590611
8
Zoom out
Zoom in
Previous page
1/28
Next page
8 GMC-I Messtechnik GmbH
Disabling Automatic Shutdown
The instrument can be switched to “CONTINUOUS ON”.
Press the FUNC key while switching the instrument on with the toggle switch
until an acoustic signal is generated. The “CONTINUOUS ON” function
is indicated at the display with the symbol.
3 Selecting Measuring Functions and Measuring Ranges
3.1 Automatic Measuring Range Selection
The multimeter is equipped with auto-ranging for all measuring ranges except for
temperature measurement, diode and continuity testing. Auto-ranging is always
activated as soon as the instrument is switched on. Depending upon the mea-
sured quantity, the device automatically selects the measuring range which
allows for best possible resolution.
The instrument automatically switches to the next highest or next lowest
measuring range for the following measured quantities:
3.2 Manual Measuring Range Selection – MAN/AUTO Key
Auto-ranging can be deactivated and ranges can be set manually in accordance
with the following table.
The manual mode is deactivated by pressing and holding the MAN/AUTO key for
about 1 s, by turning the rotary switch or by switching the instrument off and
back on again.
Measuring Ranges Resolution
Switching to the next
highest range occurs
at(... d + 1 d)
Switching to the next
lowest range occurs
1)
at (... d –1 d)
V , V , A , mA ,
A, , 30 mF, Hz,
4 ¾ 31 000 2 800
30 nF 300 F 3 ¾ 3 100 280
Key
MAN/AUTO
Function
Acknowledgement
Visual Acoustic
brief Manual mode active: utilized measuring range is fixed MAN 1 x
brief
Switching sequence for:
V: 300 mV 3V 30 V 300 V 600 V 300 mV
A: 300 A 3mA 30 mA 300 mA 3A 10 A
300 A
:30M 30  300 3k 30 k300k
3M30 M
F: 30 nF 300 nF 3 F 30 F 300 F 30 nF
Hz:
300 Hz
3kHz
30 kHz
300 kHz
1MHz
300 Hz
: 3.0000 30.000 300.00 3.0000
MAN 1 x
long Return to automatic measuring range selection 2 x
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRAport 40S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRAport 40S in the language / languages: English as an attachment in your email.

The manual is 0,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info