699093
5
Zoom out
Zoom in
Previous page
1/56
Next page
5
until earth voltage is 200 volts
or below.
Find a location for your earth
system that is permanently damp,
has high fertility or salinity and
is away from dairy sheds. Install
the earth system at least 10m (33ft)
from any power supply earth peg,
underground telephone or power cable.
The best construction is 2m (6
1
/
2
ft) long
galvanised stakes G8790 or Super Earth
Kits G8800, 3m (10ft)
apart, connected to
the Energizer by high
quality Lead-out cable
G6270. Do not use
materials that rust.
(Use G6272 if the
earth system is over
100m (300ft) from the
Energizer).
Step 1
Mount the Energizer
a) For inside use only. Mount the Energizer on a wall, out of reach of children, adjacent to
a power outlet. Install where there is no risk of the Energizer incurring fi re or mechanical
damage (illustration a).
b) Using the template on centre pages, drill 3 holes (A,B & C).
Use a 4mm (5/32”) diameter drill for timber walls or a suitable wall plug for brick and
concrete walls (illustration b).
c) Fix the screws provided into the wall, leaving the head of the screw about 3mm (1/8”) out
from the wall (illustration c).
d) Position the Energizer over the mounting screws and slide down until it is fi rmly in place.
Step 2
Connect to Earth (Ground) System
Using Lead-out Cable G6270 remove 5cm (2”) of plastic coating from one end of the cable
and attach to the green terminal on the Energizer. Attach the cable to the earth system by
removing 10cm (4”) of insulation from the cable at each Earth Stake, then clamp the exposed
wire to each stake using an Earth Clamp G8760. Tighten the clamp.
For further instructions on the earth (ground) system see “How to install earth (ground)
system” section.
Step 3
Connect the Fence
Connect Energizer’s red terminal to the fence using Lead-out Cable G6270: remove 5cm (2”)
of plastic coating from one end of the cable and attach to the red terminal on the Energizer.
Attach the other end of the cable to the fence using a Joint Clamp G6030. For instructions on
fence installation see “How to install the fence” section.
Step 4
Plug the Energizer into a power outlet
Indicator lights give you information about the Energizer and fence.
4 step installation guide
Earthing (Grounding)
Earthing the Energizer is the
key for a successful Power
Fence. Poor earthing
is the most common
reason for poor electric
fence performance. Check
the voltage on your earth system
using a Digital Volt Meter G5030.
Keep adding Earth Stakes G8790
a
b
c
G8760
G8790
Handy
hint
GREEN
RED
To Fence
To Earth System
Power/Standby Light: MR2500 Power/Standby Light: MR5000
Constant Green
Constant Yellow
Flashing Red
Constant Red
- Energizer OK, Full Power
- Energizer OK, Low Power
- Remote Control Interference
- Standby
Flashing Green
Constant Green
Constant Yellow
Flashing Red
Constant Red
- Energizer OK, Turbo Power
- Energizer OK, Full Power
- Energizer OK, Low Power
- Remote Control Interference
- Standby
Fence Light: Fence Light:
Flashes Green with each fence pulse over approx. 3.4kV
Flashes Red with each fence pulse below approx. 3.4kV
Flashes Green with each fence pulse over approx. 1.0kV
Flashes Red with each fence pulse below approx. 1.0kV
English
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gallagher MR2500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gallagher MR2500 in the language / languages: English, German, Dutch, Danish, French, Italian, Swedish, Spanish as an attachment in your email.

The manual is 0,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info