Important Information
Crossings with overhead power lines shall be avoided wherever possible. If such a crossing cannot be avoided it
shall be made underneath the power line and as nearly as possible at right angles to it.
If connecting leads and electric animal fence wires are installed near an overhead power line, the clearances
shall not be less than those shown in the table below.
Minimum clearances from power lines for electric animal fences
Power line voltage V Clearance M
Less than or equal to 1 000 3
Greater than 1 000 and less than or equal to 33 000 4
Greater than 33 000 8
If connecting leads and electric animal fence wires are installed near an overhead power line, their height above
the ground shall not exceed 3 m
This height applies either side of the orthogonal projection of the outermost conductors of the power line on
the ground surface, for a distance of
- 2 m for power lines operating at a nominal voltage not exceeding 1 000 V;
- 15 m for power lines operating at a nominal voltage exceeding 1 000 V.
Electric animal fences intended for deterring birds, household pet containment or training animals such as cows
need only be supplied from low output energizers to obtain satisfactory and safe performance.
In electric animal fences intended for deterring birds from roosting on buildings, no electric fence wire shall be
connected to the energizer earth electrode. A warning sign shall be fitted to every point where persons may
gain ready access to the conductors.
Fence wiring should be installed well away from any telephone or telegraph line or radio aerial.
Where an electric animal fence crosses a public pathway, a non-electrified gate shall be incorporated in the
electric animal fence at that point or a crossing by means of stiles shall be provided. At any such crossing, the
adjacent electrified wires shall carry warning signs.
Any part of an electric animal fence that is installed along a public road or pathway shall be identified by electric
fence warning signs (G6020) at regular intervals that are securely fastened to the fence posts or firmly clamped
to the fence wires.
The size of the warning sign shall be at least 100mm x 200mm.
The background colour of both sides of the warning sign shall be yellow.
The inscription on the sign shall be black and shall be either:
- the substance of “CAUTION: Electric Animal Fence” or,
-the symbol shown:
The inscription shall be indelible, inscribed on both sides of the warning sign and have a height of at least
25mm.
Ensure that all mains operated, ancillary equipment connected to the electric animal fence circuit provides a
degree of isolation between the fence circuit and the supply mains equivalent to that provided by the energizer.
Protection from the weather shall be provided for the ancillary equipment unless this equipment is certified by
the manufacturer as being suitable for use outdoors, and is of a type with a minimum degree of protection
IPX4.
This energizer complies with international safety regulations and is manufactured to international standards.
Gallagher reserves the right to make changes without notice to any product specification to improve reliability,
function or design. E & OE.
The author thanks the International Electrotechnical Commission (IEC) for permission to reproduce Information from its
International Publication 60335-2-76 ed.2.0 (2002). All such extracts are copyright of IEC, Geneva, Switzerland. All rights reserved.
Further information on the IEC is available from www.iec.ch. IEC has no responsibility for the placement and context in which the
extracts and contents are reproduced by the author, nor is IEC in any way responsible for the other content or accuracy therein.
Save these instructions
SERVICE OF DOUBLE-INSULATED APPLIANCES
In a double-insulated controller, two systems of insulation are provided instead of grounding. No equipment
grounding means is provided in the supply cord of a double-insulated controller, nor should a means for equipment
grounding be added to the controller. Servicing a double-insulated controller requires extreme care and knowledge
of the system, and should be done only by qualified service personnel. Replacement parts of a double insulated
controller must be identical to the parts they replace A double insulated controller is marked with the words
“DOUBLE INSULATION” or “DOUBLE INSULATED. The symbol for double insulation
may also be marked on the
appliance.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gallagher MR2500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gallagher MR2500 in the language / languages: English, German, Dutch, Danish, French, Italian, Swedish, Spanish as an attachment in your email.

The manual is 0,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info