6.2 FINAL ADJUSTMENT OF THE LIMIT SWITCHES
To correctly adjust the limit switches, the control unit must be installed and correctly connected with all the
control and safety accessories.
The stopping and deceleration of the gate, during opening and/or closing, occurs when the cams inside the device activate the
microswitches corresponding to the assigned function.
FCO = opening limit switch (screw 3)
FCC = closing limit switch (screw 2)
ROP = start of opening deceleration (screw 4)
RCL = start of closing deceleration (screw 1)
1. Prepare the operator for MANUAL operation, as described in section 8.
2. Loosen the screws and remove the limit switch unit cover (Fig. 20 ref. f g).
3. Set the sliding leaf in open position, at least 10 cm before the mechanical limit stop.
4. Loosen the central locking screw of the limit switch unit (Fig. 22 ref. e).
5. Turn the screw corresponding to the FCO opening limit switch (Fig. 21 ref. c) until the microswitch is engaged by the cam.
6. In chart 1, knowing the weight of the sliding leaf, choose the operating speed and calculate the corresponding MINIMUM STOP
SPACE S[mm].
7. Then, move the sliding leaf back in closing position according to the amount of identified STOP SPACE.
8. Turn the screw corresponding to ROP opening deceleration (Fig. 21 ref. d) until the microswitch is engaged by the cam.
9. Place the sliding leaf in closed position, at least 10 cm before the mechanical limit stop.
10. Turn the screw corresponding to the FCC closing limit switch (Fig. 21 ref. b) until the microswitch is engaged by the cam.
11. Move the sliding leaf back in opening position according to the amount of STOP SPACE identified in chart 1.
12. Turn the screw corresponding to RCL closing deceleration (Fig. 21 ref. a) until the microswitch is engaged by the cam.
13. In chart 2, knowing the weight and the operating speed of the sliding leaf, calculate the corresponding DECELERATION TIME t[s].
ROP - RCL MINIMUM STOP SPACE
DECELERATION TIME
Chart 1
Chart 2
Example:
P = 1000 kg
V = 0.6 m/sec
S = 400 mm
Example:
P = 1000 Kg
V = 0.6 m/sec
t = 1.7 sec
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for FAAC C850 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of FAAC C850 in the language / languages: English as an attachment in your email.

The manual is 13,57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info