FSWOP
FSWCL
OP_A
OP_B
STOP
FCA1
FCA2
FCC1
FCC2
FSWOP
FSWCL
OP_A
OP_B
STOP
FCA1
FCA2
FCC1
FCC2
This display shows the normal
status of the control panel.
This display shows the
meaning of each LED.
Figure 16. The 455 D display.
Page 17
January, 2004
412 Operator And
455 D Control Panel Installation Manual
THE 455 D CONTROL PANEL INSTALLATION INSTRUCTIONS
ACTIVATING DEVICES AND RADIO RECEIVER: The
activating devices and radio receiver for your gate must
have normally open (N.O.) contacts. Connect such
devices to terminals 9 and 14.
N
OTE: The FAAC radio receiver plugs into the 5
prongs labeled J2 (Quick connect port).
Page 19 shows how to connect a three or four wire
receiver.
DECODER CARD: If you are installing the Digicard
magnetic card reader, or the Digikey keyboard, use the
quick-fit connector J2 for the DS decoder card.
N
OTE: If your using both a receiver and decoder,
hard wire the decoder and plug in the receiver.
OPEN/HOLD OPEN DEVICE: To open and hold open the
gate, simply maintain a contact across terminals 9 and
14. (“A” Mode only)
STOP BUTTON: The stop button you install must have
normally closed (N.C.) contacts. Multiple stop buttons
must be wired in series. Connect your stop device
between terminals 11 and 16.
N
OTE: The 455 D will not operate the motors
without a closed circuit between 11 & 14.
The LED Indicators: The nine light emitting diodes
(LEDs) on the control panel can be used to check for the
proper function of the devices attached to the panel.
The LED lights are on whenever the contacts are closed
across each of the respective terminals.
OP_A and OP_B (Partial Opening) should illuminate only
when an activating signal is sent for 2 and 1 gate leaves,
respectively. STOP should be illuminated except when
the stop button is pressed. FSWOP and FSWCL should be
illuminated except when the reversing devices, for
Figure 15.
Wiring detail (a) inside
the junction box and
(b) from the junction
box or operator to the
high-voltage terminal
strip on the 455 D
control panel
LED On Off
OP_A
Command Given No Command
OP_B Command Given No Command
Stop No Command Command Given
FSW
Open
Opening reversing
devices clear
Reversing device
triggered
FSW
Close
Closing reversing
devices clear
Reversing device
triggered
FCA1
FCC1
Flashes when gate coder is in use.
Operator 1
FCA
2
FCC
2
Flashes when gate coder is in use.
Operator 2
U.L. Listed Control Panel Enclosure
Cord grip or
conduit from
U.L. Listed gate
operator(s)
(b)
Op.1 Op.2
COM OP CL COM OP CL
J3 J4
High-voltage
terminal strip
455 D Control Panel
Ground
J1
To the U. L. Listed gate operator
To the U.L. Listed
control panel
U.L. Listed
cord grip
Junction box
Legend
White
Red
Black
Yellow/
Green
(a)
Conduit to U.L. Listed
control panel enclosure
according to N.E.C.
17


Need help? Post your question in this forum.

Forumrules
1

Forum

faac-455

Reset search

  • Looking for set up program for 455A control board to FAAC 760 dual gate
    Submitted on 9-7-2023 at 01:41

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for FAAC 455 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of FAAC 455 in the language / languages: English as an attachment in your email.

The manual is 0,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of FAAC 455

FAAC 455 User Manual - Dutch - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info