119529
27
Zoom out
Zoom in
Previous page
1/28
Next page
Page 27
January, 2004
412 Operator And
455 D Control Panel Installation Manual
TROUBLESHOOTING
PROBLEM: THE GATE DOES NOT RESPOND TO
AN ACTIVATING SIGNAL.
SOLUTION:
You should have at least one operator wired to
terminals 1,2 and 3.
Be sure that you have the motor start capacitors wired in
terminals 2 and 3, 5 and 6 with the directional leads.
Be sure that the torque/force setting is at the maximum
setting of 50 in programming for hydraulic operations.
Verify that the LEDs FSWOP, FSWCL, and the STOP are
illuminated. If they are not illuminated, be sure that you
have closed circuits in the stop and reversing inputs.
Verify that your activating device works properly. OP_A
should illuminate when you signal the gate to open. If
OP_A does not illuminate when you signal the gate, then
the problem may be in your activating device. Short
across terminals 9 and 14. If the short causes the gate
to open, then the problem is in the activating device.
Repair or replace the device
.
PROBLEM: THE GATE DOESN'T OPEN (OR CLOSE)
THOUGH THE MOTORS ARE RUNNING.
SOLUTION:
Make sure that the motor is running in the right
direction, and make sure the Manual Release
mechanism has fully engaged the system.
PROBLEM: THE GATE OPENS BUT DOES NOT
CLOSE.
SOLUTION:
Make sure you have selected the desired operating
mode.
Verify that the reversing devices are working properly.
FSWOP and FSWCL should be illuminated except when a
reversing device is triggered. If either does not
illuminate, then one of your reversing devices is
preventing the gate from responding to your signal.
Check your reversing devices.
If no reversing devices are installed, make sure a circuit
is installed between appropriate terminals.
PROBLEM: THE GATE DOES NOT FULLY OPEN
(OR CLOSE).
SOLUTION:
Check the operator's open/close time selection. You
should set a time that is just longer than the rated
speed of your model of operator. For example, because
the 412 CBAC has a rated opening time of 13 sec, you
should set the time at 20 or 25 seconds.
Check to see that there are no obstructions in the path
of the gate or that the hinges are not binding.
PROBLEM: THE OPERATOR DOESN'T WORK
SMOOTHLY AND THE GATE JERKS AS IT OPENS
AND CLOSES.
SOLUTION:
Make sure the Manual Release Mechanism has fully
engaged the worm screw operation of the operator.
Make sure that a flexible gate leaf is not the problem. If
the gate leaf flexes, then stiffen the gate or use a slower
operator.
WARNING! Before you do any work on the control panel,
be sure to turn off the main power.
NOTE: Any control panel specific information in the following applies to the 455 D control panel only.
27


Need help? Post your question in this forum.

Forumrules
1

Forum

faac-455

Reset search

  • Looking for set up program for 455A control board to FAAC 760 dual gate
    Submitted on 9-7-2023 at 01:41

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for FAAC 455 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of FAAC 455 in the language / languages: English as an attachment in your email.

The manual is 0,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of FAAC 455

FAAC 455 User Manual - Dutch - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info