119529
18
Zoom out
Zoom in
Previous page
1/28
Next page
E (semi-automatic): This mode requires a
command to open and a command to close.
A second command during opening stops the
gate. A second command during closing
reopens the gate.
EP (semi-automatic, step by step): This
mode requires a command to open and a
command to close. A second command
during opening or closing causes the gate to
stop. A third command then reverses the
previous motion of the gate.
B (manned, pulsed): This mode is designed
for guard station use and requires a three-
button switch (pulsed) to open, close, and
stop the gate.
C (manned and constant): This mode
requires constant pressure switches. One to
open and one to close. No pressure on a
switch stops the gate.
The three programming push buttons allow the
programming of the torque (or pressure), the pause
time between opening and closing, and the leaf delay
on closing.
WARNING! Turn the main power off before you
make any electrical connections.
For all FAAC hydraulic operators using the 455 D
control panel, the force must be set at its maximum
setting of 50 in order to supply the correct voltage to
the operator.
PAUSE TIME: The pause time between opening and
closing can be adjusted from 0 seconds to 4 minutes.
Time is adjusted in one-second increments from 0—
59 seconds. When 60 seconds is reached, time is
adjusted in 10 second increments up to 4 minutes.
i.e. if display shows 2.5, it means 2 minutes and 50
seconds.
LEAF DELAY: You may choose to delay one leaf on
closing for overlapping gate leaves. Be sure the
operator on the leaf for delayed closing is connected
to Motor 1. On opening, the leaf connected to Motor 2
is delayed 2.5 sec.
N
OTE: If an opening leaf delay is desired, it must
be enabled in the Advance Programming.
However, if enabled, you cannot adjust this
opening delay of the operator connected to
Motor 2.
The closing leaf-delay time is adjustable from 0 to 4
minutes.
NOTE: If the opening/closing time is set at less
than the leaf delay time, the delayed leaf closes
at the end of the closing time.
opening and closing, respectively, are triggered. Use
the LEDs and the next table to determine if the
accessory devices you have installed are operating
properly.
Electric Locks: An electric lock can be wired to
the 455 D in
terminals 18 and 21 (12Vac pulsed
provided). If a reversing stroke is needed to allow the
electric lock to release, this must be done in advanced
programming.
See page 19 for the connections for a magnetic locking
device.
WARNING LIGHT: Connect a warning light to
terminals 18 and 20 in the group labeled W.LIGHT
in terminal block J1 and J5. The terminals provide
an output voltage of 24 VDC, maximum power 3
Watts. This output voltage will power most 24 VDC
warning lights.
N
OTE: The behavior of the warning light varies
according to the logic you have set.
LOGICS A, S, E, EP, AND B: The warning light is on
steadily during opening and the pause phase. During
closing, the light flashes.
LOGIC C: The warning light is on steadily during
opening and flashes during closing.
SET OTHER OPERATING CONTROLS
WARNING
! Turn the main power off before you
make any electrical connections.
You need to program the control panel for your gate's
operation. The 455 D Control Panel has on board
programming that controls a wide range of functions.
OPERATING LOGICS
NOTE: The 455 D Control Panel provides inputs
for opening reversing devices and closing
reversing devices. FAAC strongly recommends
the use of reversing devices, such as photocells
or other non-contact sensors.
A (automatic): The gate opens on command
and automatically closes after a pause phase. A
second command while opening is ignored; a
second command during the pause phase
interrupts the pause time; a second command
during closing reopens the gate. A maintained
open command will hold the gate open.
S (security): The security mode is like A logic
except that a second command during opening
immediately closes the gate. A maintained
open command will not hold the gate open.
Page 18
January, 2004
412 Operator And
455 D Control Panel Installation Manual
THE 455 D CONTROL PANEL INSTALLATION INSTRUCTIONS
18


Need help? Post your question in this forum.

Forumrules
1

Forum

faac-455

Reset search

  • Looking for set up program for 455A control board to FAAC 760 dual gate
    Submitted on 9-7-2023 at 01:41

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for FAAC 455 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of FAAC 455 in the language / languages: English as an attachment in your email.

The manual is 0,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of FAAC 455

FAAC 455 User Manual - Dutch - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info