Detector will not illuminate when the Detector is
triggered, (unless in test mode). However, under low
battery conditions this LED will be illuminated for
approx. 1 second when the detector is triggered.
When this occurs the batteries should be replaced as
soon as possible.
The Magnetic Contact Detector has the facility to
connect an additional wired Magnetic Contact. This
additional contact must be of a normally closed contact
type with the contacts being opened in order to
generate an alarm condition.
Any number of Magnetic Contact Detectors can be
used with the system, providing they are all coded with
the system house code and are mounted within
effective radio range of the Control Panel.
CHOOSING A MOUNTING LOCATION
The Magnetic Contact Detector is suitable for mounting
in dry interior locations only.
Decide which doors/windows are to be protected by
fitting Magnetic Contact Detectors, (usually the front
and back doors as a minimum will have Magnetic
Contact Detectors fitted). Additional detectors may
also be fitted where required to other vulnerable doors
or windows, (e.g. garage, patio/conservatory doors
etc).
Ensure that the position selected for the Magnetic
Contact detector is within effective range of the Control
Panel, (refer to ‘Testing the Control Panel & Remote
Control’).
Note: Take care when fixing the Detector to a metal
frame, or mounting within 1m of metalwork (i.e.
radiators, water pipes, etc) as this could affect the radio
range of the device. If required, it may be necessary
to space the magnet and detector away from the metal
surface using a plastic or wooden spacer to achieve the
necessary radio range.
INSTALLING THE MAGNETIC CONTACT
DETECTORS
Ensure that the system is in Test Mode.
1. Remove the battery cover by sliding and lifting it off.
(DO NOT use a screwdriver to lever the cover off)
2. Remove the battery holder by carefully tilting up the
end and pulling the connector off of the printed
circuit board.
3. Mount the Detector to the fixed part of the frame
along the opening edge opposite the hinges using
either the double sided adhesive tape or screws
provided.
If fixing the Detector with screws; fit the Keyhole
slot in the top of the Detector over the head of the
smaller pan-head screw. Secure the bottom of the
Detector using the 12mm countersunk head screw
fitted within the battery compartment. You will
need to drill out the centre of the fixing screw hole
using a 3mm drill. Do not over-tighten the fixing
screws as this may distort or damage the casing.
4. Fit the Magnet to the moving part of the
door/window opposite the Detector using the
adhesive tape or 15mm fixing screws. Ensure that
the parallel gap between the Magnet and Detector
is less than 10mm and that the arrow on the
Magnet is pointing towards and aligned with the
mark on the Detector.
12
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elro AP5500 - Pro Alarm System at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elro AP5500 - Pro Alarm System in the language / languages: English as an attachment in your email.

The manual is 3,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Elro AP5500 - Pro Alarm System

Elro AP5500 - Pro Alarm System Quick start guide - English - 8 pages

Elro AP5500 - Pro Alarm System Quick start guide - German - 10 pages

Elro AP5500 - Pro Alarm System Quick start guide - Dutch - 8 pages

Elro AP5500 - Pro Alarm System User Manual - Dutch - 42 pages

Elro AP5500 - Pro Alarm System Quick start guide - French - 9 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info