Note: When the system is armed, household pets
should not be allowed into an area protected by a
PIR detector as their movement would trigger the
PIR and generate an alarm.
Note: DO NOT fix the detector to metalwork or
locate the unit within 1m of metalwork (i.e. radiators,
water pipes, etc) as this could affect the radio range
of the device.
INSTALLING THE PIR DETECTORS
Ensure that the system is in Test Mode.
1. Undo and remove the fixing screw from the bottom
edge of the PIR. Carefully pull the bottom edge of
the detector away from the rear cover and then slide
down to release the top clips.
7. To refit the PIR detector to the rear cover, offer the
detector up to the rear cover and locate the clips in
the top edge into the rear cover. Push the lower
edge of the detector into place and refit the fixing
screw in the bottom edge of the PIR to secure in
position. Do not over-tighten the fixing screws as
this may damage the casing.
SETTING THE PIR DETECTORS
Located on the PCB of the PIR Detector are two blocks
of DIP switches (SW2 and SW3).
Rear Cover
Fixing
Screw
2. Carefully drill out the required mounting holes in the
rear cover using a 3mm drill according to whether
the unit is being mounted in a corner or against a
flat wall.
3. Using the rear cover as a template, mark the
positions of the fixing holes on the wall.
4. Fix the rear cover to the wall using the two 18mm
No.4 screws and 25mm wall plugs, (a 5mm hole
will be required for the wall plugs). Do not over-
tighten the fixing screws as this may distort or
damage the cover.
5. Configure the PIR detector as described below.
Remember that on initial installation that the device
needs to be tested and should therefore be set in
Walk Test Mode.
6. Check that the detector PCB is located and set in
the correct position to give the detection zone
pattern required.
To adjust the PCB position, simply slide it up or
down ensuring that the location legs are aligned
with the required position number marked on the
board.
10
1. DIP switches SW2 (numbered 1-8) are used to set
the House Code for the PIR Detector and must be
set to the same ON/OFF combination as the House
Code DIP switches in all other system devices.
2. Set the alarm zone which the detector will operate
on with DIP switches 1-3 of SW3 as follows:
DIP 1
DIP 2
DIP 3
Zone 1
OFF
OFF
OFF
Zone 2
OFF
OFF
ON
Zone 3
OFF
ON
OFF
Zone 4
OFF
ON
ON
Zone 5
ON
OFF
OFF
Zone 6
ON
OFF
ON
3. DIP 4 of SW3 is used to configure the PIR Detector
for walk test mode, which allows the operation of
the detector to be checked during installation
without triggering a Full Alarm.
ON Walk Test mode
OFF Normal mode
Note: On initial installation the detector should be
set into Walk-Test mode ready for testing.
4. The PIR Detector incorporates an anti-false alarm
feature designed to compensate for situations
Mounting Hole
Positions
Dip Switches
PCB Position
Indicator
PCB Board
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elro AP5500 - Pro Alarm System at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elro AP5500 - Pro Alarm System in the language / languages: English as an attachment in your email.

The manual is 3,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Elro AP5500 - Pro Alarm System

Elro AP5500 - Pro Alarm System Quick start guide - English - 8 pages

Elro AP5500 - Pro Alarm System Quick start guide - German - 10 pages

Elro AP5500 - Pro Alarm System Quick start guide - Dutch - 8 pages

Elro AP5500 - Pro Alarm System User Manual - Dutch - 42 pages

Elro AP5500 - Pro Alarm System Quick start guide - French - 9 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info