5.2Connection
5.2.1Gasconnection
Place a gas tap in the gas pipe in accordance with the applicable regulations.
!Caution
Make sure there is no dirt in the gas pipes and connections.
No soldering may take place at the flexible gas hose(s), as this could cause leaks.
The following requirements apply to the gas connection:
use a gas pipe with the correct dimensions, so that no pressure loss can occur;
the gas tap must be approved (in the EU this will be the CE mark);
you should always be able to reach the gas tap.
5.2.2Electricconnection
In case of a 230 Volt electrical connection, provide proper grounding, if applicable.
Place this electrical connection away from the appliance, as low as possible in the chmney breast.
This has to do with the temperature development in the chimney breast.
If possible, place the receiver after any building work has been completed.
If this is not possible:
!Caution
Protect the receiver against dust and moisture created during the building process!
5.3Placingtheappliance
!Caution
Unless stated otherwise: always place the appliance with a minimum distance of 500 mm from combustible
objects or materials;
Place the discharge pipes in such a way that situations with risk of fire can never occur;
Always place the appliance in front of a wall of non combustible and heat-resistant material;
Always maintain a minimum distance between appliance and back wall, if indicated in the dimensional
drawing (Appendix 3, fig. 2);
Take sufficient measures to prevent high temperatures of a possible wall behind the chimney breast,
including the materials and/or objects that are behind the wall;
Do not cover the appliance and/or do not wrap it in an insulation blanket or any other material;
Make sure that the appliance to be installed has a stable position. Attach the appliance, if applicable, to the
wall using the wall brackets and/or fasten the extending legs with self-tapping screws.
!Caution
When installing an appliance that has to be built in, take the following into account:
The minimum construction dimensions according to Appendix 3, fig. 1 and 2.
Ø
Provide a gas connection at the location. For details (see section 5.2).
Ø
Make a passage for the flue gas discharge system or the concentric system with the following diameters; for
details, see section 5.7 or 5.8:
the pipe diameter +10 mm for a passage through non combustible material;
the pipe diameter +100 mm for a passage through combustible material.
!Caution
Starting at section 5.9, you will find additional instructions that are specifically needed for the installation of your
appliance.
5.4Placingabuiltinappliance (if applicable)
Not all DRU built in appliances are supplied with a control hatch. If not included in the delivery, this control hatch
is available separately. In case of appliances with closed combustion (type C11/C31) we always recommend using
the Dru control hatch. In case of appliances with open combustion (type B 11 AS/BS), a control hatch is not required.
In this section we assume an application with control hatch.
!Caution
If you do not use a recommended Dru control hatch, please strictly observe the safeguards and necessary
instructions stated in chapters 5.4 to 5.6.
If you are not using the control hatch, please take the following into account as well:
the accessibility of components that are normally placed in the control hatch;
the maximum temperature of these components (maximum 55 °C).
The gas control is mounted under the appliance, at the burner mounting plate. It must be taken out and placed in
the control hatch at a later time. For placing the gas control in the control hatch, see section 5.6.
6
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for DRU Diablo Next at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of DRU Diablo Next in the language / languages: English as an attachment in your email.

The manual is 4.59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of DRU Diablo Next

DRU Diablo Next User Manual - English - 20 pages

DRU Diablo Next Installation Guide - German - 36 pages

DRU Diablo Next User Manual - German - 20 pages

DRU Diablo Next Installation Guide - Dutch - 36 pages

DRU Diablo Next User Manual - Dutch - 20 pages

DRU Diablo Next User Manual - Dutch - 16 pages

DRU Diablo Next User Manual - French - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info