INSTALLATION MANUAL
3.4Secondthermocouplesafety (if applicable, see Appendix 2, Table 2)
It is possible, that the appliance to be installed has 2 thermocouples. Thermocouple 1 is always next to the pilot
burner, thermocouple 2 is always elsewhere above the main burner.
If the appliance is provided with a second thermocouple safety on the main burner, you need to know that it will
intervene if no proper transfer has taken place from the pilot burner to the main burner or from the main burner
itself. The gas supply will be interrupted after 22 seconds. In order to solve a poor or non-existent transfer from the
pilot burner to the main burner, please use the malfunction search diagram in Appendix 1.
3.5Oxypilotsafety (if applicable, see Appendix 2, Table 2)
If the appliance is provided with an oxypilot safety, you need to know that it will intervene (the pilot flame and the
gas supply to the main burner will be switched off) if insufficient combustion air (oxygen) is supplied and/or if the
discharge system has insufficient thermal draught.
Once the supply of combustion air is sufficient again, the appliance can be restarted.
The supply of fresh air can be controlled by installing/opening ventilation holes in the room where the appliance
is installed.
4.Removingthepackaging
Note the following items when removing the packaging:
Ø
Remove all packaging materials.
Ø
Remove all supplied components in, on and/or at the appliance.
Ø
Check the appliance and accessories for damages (during transport).
Ø
If necessary, contact your supplier.
Ø
Never install an appliance that is damaged !
Ø
Remove any screws that are used to fix the appliance to a platform or pallet.
!Caution
The glass pane(s) is/are made of a ceramic material. Very small irregularities in the glass pane(s) cannot be
avoided, but are within the required quality standards.
!Caution
Keep plastic bags away from children.
In Appendix 2, Table 1 you can see which parts you should have after removing the packaging.
Ø
Contact your supplier if you do not have all the parts after you finished removing the packaging.
Ø
Dispose of packaging in accordance with local regulations.
5.Installation
Read this manual carefully to ensure the proper and safe installation of the appliance.
!Caution
Install the appliance in the order described in this chapter.
Ø
Please install the appliance in accordance with the applicable national, local and constructional (installation)
regulations.
Ø
Observe the regulations/instructions in this manual.
5.1Typeofgas
The data plate indicates for which type of gas, gas pressure and for which country this appliance is intended.
The data plate can be found on the appliance or can be attached to a chain to which it should remain attached.
!Caution
Check whether the appliance is suitable for the type of gas and the gas pressure used at the location.
5.1.1Reconstructiontodifferenttypeofgas
If you want to convert this appliance into a different type of gas, please contact DRU's service department and ask
what is possible. Reconstructions should only be performed by authorized gas installers.
5
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for DRU Diablo Next at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of DRU Diablo Next in the language / languages: English as an attachment in your email.

The manual is 4.59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of DRU Diablo Next

DRU Diablo Next User Manual - English - 20 pages

DRU Diablo Next Installation Guide - German - 36 pages

DRU Diablo Next User Manual - German - 20 pages

DRU Diablo Next Installation Guide - Dutch - 36 pages

DRU Diablo Next User Manual - Dutch - 20 pages

DRU Diablo Next User Manual - Dutch - 16 pages

DRU Diablo Next User Manual - French - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info