Service level menu (for qualified heating engineers only)
Logamatic SC40 - Technical specifications are subject to change without prior notice.
58
7
7.5.6 Cylinder 1 maximum temperature
Menu: Service > Settings > Cylinder 1 maximum temperature
When the temperature detected by the cylinder temperature sensor reaches the maximum cylinder
temperature, charging of the cylinder is stopped.
7.5.7 Double Match Flow
Menu: Service > Settings > Double Match Flow
This function is used for quick charging of the top part of the cylinder to 45 °C to reduce the amount
of time the domestic hot water is reheated by the boiler.
This function is only possible when Speed modulation is active.
If the Daily heating function is also used, the Double match flow function may be limited as the
necessary sensor position for Daily heating (top 1/3 of the cylinder) may be within the part of the
cylinder reheated by the boiler.
7.5.8 Return boost cut-in temperature differential
Menu: Service > Settings > Reserve bypass cut-in temperature differential
If the Return boost function is active, the temperature of the solar storage cylinder is compared with
the return temperature of the heating system. If necessary, the return boost valve is opened to feed
heat from the solar system from the thermal store into the heating system.
The minimum difference from the cut-out temperature difference is 3 K (°C).
Setting range Default setting New setting
20 - 90 °C 60 °C
Tab. 19
Setting range Default setting New setting
Yes/No No
Tab. 20
Setting range Default range setting New setting
6 - 20 K (°C) 6 K (°C)
Tab. 21
58


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Buderus Logamatic SC40 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Buderus Logamatic SC40 in the language / languages: English as an attachment in your email.

The manual is 1,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Buderus Logamatic SC40

Buderus Logamatic SC40 Usermanual and installation guide - German - 76 pages

Buderus Logamatic SC40 User Manual - Dutch - 16 pages

Buderus Logamatic SC40 Installation Guide - Dutch - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info