Service level menu (for qualified heating engineers only)
Logamatic SC40 - Technical specifications are subject to change without prior notice.
56
7
7.5.2 Solar system pump 1 speed modulation
Menu: Service > Settings > Solar system pump 1 speed modulation
The speed modulation function improves the efficiency of the solar thermal system by keeping the
temperature difference within the set cut-in temperature differential.
If the “Double match flow” function is active, the speed is controlled by that function. We recom-
mend leaving this setting activated.
7.5.3 Solar system pump 1 minimum output
Menu: Service > Settings > Solar system pump 1 minimum output
This setting determines the minimum speed of the solar system pump.
In systems with external heat exchanger and 2 heat consumers or systems with external heat
exchanger and East/West aspect function, the pump is run at 100 %.
The minimum pump output for solar system pumps 1 and 2 is always the same with configurations
T3, T7 and H3 (if the output for one pump is changed, the controller sets the others to the same
output).
Warning: risk of damage to system due to pump failure.
V If a pump with internal electronic control circuitry is connected, deactivate the
speed modulation function on the controller.
Setting range Default setting New setting
Yes/No Yes
Tab. 15
Setting range Default setting New setting
30 - 100 % 50 %
Tab. 16
56


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Buderus Logamatic SC40 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Buderus Logamatic SC40 in the language / languages: English as an attachment in your email.

The manual is 1,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Buderus Logamatic SC40

Buderus Logamatic SC40 Usermanual and installation guide - German - 76 pages

Buderus Logamatic SC40 User Manual - Dutch - 16 pages

Buderus Logamatic SC40 Installation Guide - Dutch - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info