Service level menu (for qualified heating engineers only)
7
7.5.4 Collector maximum temperature
Menu: Service > Settings > Collector maximum temperature
If the collector maximum temperature is exceeded, the solar system pump is switched off or (if
already off) not switched on.
7.5.5 Evacuated tube collector function
Menu: Service > Settings > Tube collector function
In order to pump the heated solar solar fluid to the temperature sensor with evacuated tube collec-
tors, between the hours of 6:00 am and 10:00 pm and upwards of a collector temperature of 20 °C,
the solar system pump is switched on briefly every 15 minutes.
This function is not possible or is limited if the collector sensor is external to the collector.
Setting range Default setting New setting
100 - 140 °C 120 °C
Tab. 17
Setting range Default setting New setting
Yes/No No
Tab. 18
If the Tube collector function is active, the cooling function (Æ Section 7.5.22,
page 65) is automatically deactivated.
57


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Buderus Logamatic SC40 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Buderus Logamatic SC40 in the language / languages: English as an attachment in your email.

The manual is 1,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Buderus Logamatic SC40

Buderus Logamatic SC40 Usermanual and installation guide - German - 76 pages

Buderus Logamatic SC40 User Manual - Dutch - 16 pages

Buderus Logamatic SC40 Installation Guide - Dutch - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info