Date and time is programmed and the fault is reset. Refer to System Setting, page 61 for more
information.
Supervise:
1. Report the date and time fault to the configured destination programmed on location
124.
2. Slow flash FAULT indicator (refer the detailed description in chapter keypad indicators)
3. No report to the AMAX panel system, when date and time setting is recorded in
nonvolatile memory and AMAX Panel is reset. The FAULT indicator is turned off when
there is no other system fault.
6 - Communication Failure
Communication Fault 1 - 4
Condition:
Panel cannot send the report to the Destination 1 after 4 attempts.
Restore:
The fault is reset when the first kissoff tone is received and fault is reset.
Supervise:
1. Report the fault to configured destination on address 124 when the fault is detected.
2. Slow flash FAULT indicator (refer the detailed description in chapter keypad indicators).
3. When the fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off when there is no other system fault.
7- Tamper
System Tamper
Onboard Tamper Condition is registered when the Onboard Tamper input is open.
Condition:
Onboard Panel Tamper input is open.
Restore:
The Tamper condition is reset when the Input is shorted and Tamper condition is reset.
Supervise:
1. Report the Tamper condition to configured destination on Address 124 when the Tamper
Condition is detected.
2. Slow flash FAULT indicator (refer the detailed description in chapter keypad indicators).
3. When the Tamper Condition is reset, send the restored report to the configured
destinations.
Keypad Tamper
Condition:
Keypad 1 is opened and the Tamper contact is triggered.
Restore:
The Tamper condition is reset when the Keypad is closed and Tamper condition is reset.
Supervise:
1. Report the Tamper condition to configured destination on Address 124 when the Tamper
Condition is detected.
2. Slow flash FAULT indicator (refer the detailed description in chapter keypad indicators).
3. When the Tamper Condition is reset, send the restored report to the configured
destinations. The FAULT indicator is turned off when there is no other system fault.
Zone Expansion Module Tamper
Zone expansion module 1 to 6 tamper
AMAX 2100 / 3000 / 4000
Troubleshooting | en 147
Bosch Sicherheitsysteme GmbH Installation Guide 2013.10 | 01 | F.01U.267.112
147


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch AMAX 4000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch AMAX 4000 in the language / languages: English as an attachment in your email.

The manual is 3,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch AMAX 4000

Bosch AMAX 4000 User Manual - English - 24 pages

Bosch AMAX 4000 User Manual - English - 36 pages

Bosch AMAX 4000 Quick start guide - English - 38 pages

Bosch AMAX 4000 Installation Guide - German - 170 pages

Bosch AMAX 4000 Quick start guide - German - 34 pages

Bosch AMAX 4000 Installation Guide - Dutch - 166 pages

Bosch AMAX 4000 User Manual - Dutch - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info