697457
143
Zoom out
Zoom in
Previous page
1/158
Next page
3. When the fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off when there is no other system fault.
RF Sensor Fault
Condition:
Any one wireless zone is abnormal (e.g., Remove the pyro from the smoke detector / ...) and
wireless module is enable.
Restore:
All wireless zone are normal and wireless module is enabled and fault is reset.
Supervise:
1. Report the wireless zone fault to configured destination when the fault is detected.
2. Slow flash FAULT indicator (refer to Keypad Indicators for the detailed description).
3. When the fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off when there is no other system fault.
RF Repeater Failure
1-8 RF Repeater 1-8 Missing
Condition:
No status report to receiver in the RF supervision interval and wireless module is enable.
Restore:
Have status report to receiver in the RF supervision interval and wireless module is enable and
fault is reset.
Supervise:
1. Report the repeater missing fault to configured destination when the fault is detected.
2. Slow flash FAULT indicator (refer to Keypad Indicators for the detailed description).
3. When the fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off when there is no other system fault.
RF Config Failure
Configuration Conflict Sensors
Condition:
Any one wireless zone configuration is error.
Restore:
All wireless zone configuration are correct and fault is reset.
Supervise:
1. Slow flash FAULT indicator (refer to Keypad Indicators for the detailed description).
2. When the fault is reset, the FAULT indicator is turned off when there is no other system
fault.
Configuration Conflict Repeaters
Condition:
Any one repeater configuration is error.
Restore:
All repeater configuration are correct and fault is reset.
Supervise:
1. Slow flash FAULT indicator (refer to Keypad Indicators for the detailed description).
2. When the fault is reset, the FAULT indicator is turned off when there is no other system
fault.
Configuration Conflict Keyfobs
Condition:
Any one keyfob configuration is error.
Restore:
AMAX 2100 / 3000 / 4000
Troubleshooting | en 143
Bosch Sicherheitsysteme GmbH Installation Guide 2013.10 | 01 | F.01U.267.112
143


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch AMAX 4000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch AMAX 4000 in the language / languages: English as an attachment in your email.

The manual is 3,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch AMAX 4000

Bosch AMAX 4000 User Manual - English - 24 pages

Bosch AMAX 4000 User Manual - English - 36 pages

Bosch AMAX 4000 Quick start guide - English - 38 pages

Bosch AMAX 4000 Installation Guide - German - 170 pages

Bosch AMAX 4000 Quick start guide - German - 34 pages

Bosch AMAX 4000 Installation Guide - Dutch - 166 pages

Bosch AMAX 4000 User Manual - Dutch - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info