Installation
www.bora.com
The exhaust air must be directed outside or to the
recirculation unit through appropriate ducts.
For further planning examples and notices, please see
the ventilation handbook (not included in the scope of
delivery).
Installing the additional fan
Install the additional fan in the exhaust duct.
Ensure that a minimum clearance of 300 cm is
maintained between the fan units.
Only use BORA universal fans with your BORA cooktop
extractor system.
Operating the cooktop extractor with a
fireplace that depends on the air in the room
INFO The state and regional laws and regulations
must be observed with regard to the exhaust
duct design. A sufficient air supply must be
ensured.
Fireplaces that depend on the air in the room (e.g. gas,
oil, wood or coal-fired heaters, continuous-flow water
heaters, instantaneous water heaters) draw in air from
the room in which they are installed and release the
exhaust fumes into the outside air via an exhaust system
(e.g. chimney).
If the cooktop extractor is used in exhaust mode, it draws
in air from the room in which it is installed as well as from
neighbouring rooms. If there is insufficient air supply, low
pressure will occur. Toxic gases could be drawn out of the
chimney or extraction ducting and back into the room.
Fig. 6.24 Exhaust air installation – not permitted
Fig. 6.25 Exhaust air installation – correct
6.5.4 Installation – standard set-up
1
2
3
4
5
6
7
Fig. 6.23 Standard set-up
[1] Cooktop extractor
[2] 90° diverter
[3] Horizontal tube bend
[4] Silencer
[5] Universal plinth fan
[6] Air duct/recirculation unit
[7] Universal control unit
Push the tube bend [3] onto the exhaust fitting of the
cooktop extractor [1].
Push the 90° diverter [2] onto the tube bend [3].
Position the plinth fan [5].
To facilitate positioning, the inlet nozzle on the plinth
fan can be removed. To do this, please see the assembly
instructions for the ULS25 universal plinth fan.
Connect the silencer [4] to the plinth fan [5].
Connect the silencer [4] to the 90° diverter [2].
Use the UDB25 sealing tape (not included in the scope
of delivery) to adhere together the connections for the
ducting sections with an air tight join.
You can also optimally adhere together the connections
between the ducting sections and the plinth fan with
UDB25 sealing tape.
INFO Position the plinth fan and the universal
control unit in such a way that they are easily
accessible and removable for maintenance
work.
The maximum exhaust air duct length with a fan is 6 m.
The minimum cross-section of the air ducts must
be 176 cm
2
, which equates to a round pipe with a
diameter of 150 mm.
For the ducting, only use stable duct elements with
smooth pipe interiors. Do not use flexible or fabric
tubes.
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bora PL540E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bora PL540E in the language / languages: English as an attachment in your email.

The manual is 3,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bora PL540E

Bora PL540E User Manual - German - 36 pages

Bora PL540E User Manual - Dutch - 36 pages

Bora PL540E User Manual - French - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info