714384
22
Zoom out
Zoom in
Previous page
1/36
Next page
EN
22
Installation
www.bora.com
1
2
4
3
Fig. 6.29 Open the universal control unit’s cover
[1] Cover
[2] Electronic unit
[3] Base unit
[4] Switch contact clamp
INFO The electronic unit [2] can contain residual
charge. You must therefore be careful not to
touch the exposed contacts on the electronic
unit!
Preparing connection cables for external
switching equipment
Use the following types of connection cables from the
following manufacturers to connect external switching
equipment.
Contact Connection cable
Home-In H03VV-F 2x0.5mm²
Home-Out H03VVH2-F 2x0.75mm²
Tab. 6.5 Connection cable
INFO The connection cable is only intended for
indoor use in buildings, private homes,
kitchens or offices!
INFO The overall length of the connection cable for
external switching equipment must not exceed
10 m!
For reasons of electromagnetic compatibility, all connection
cables from external switch devices must be filtered
with a ferrite sleeve. This is not included in the scope of
delivery.
Use the order code UFH (universal filter sleeve) to
order the filter sleeve from your specialist supplier or
contact BORA via the website at www.bora.com.
Contact your BORA specialist supplier to replace any
damaged components.
Connecting the additional fan
Connect the fan’s control line [1] to the universal
control unit [5].
Connect the fan’s power supply cable [2] to the
universal control unit [7].
Check all the plug connections to ensure that they are
secure.
6.7 Connecting external switch
contacts
INFO The Home-In and Home-Out communication
connections must only be connected by a
certified specialist. The specialist also
assumes responsibility for the proper
installation and commissioning.
When using Home-In and Home-Out, you will require the
relevant documents for the external switch devices in
order to ensure safe device connection and operation.
The following switch contacts can be used:
Contact Function Connection
Home-In Cooktop extractor on/off
connection for external switch
contact (contact closed:
cooktop extractor on)
24 VDC
100 mA
Home-Out Electrically isolated contact for
controlling external installations
depending on the operating
status of the cooktop extractor
(cooktop extractor on: contact
closed)
Maximum 250
VAC / 30
VDC, 2.5A
Tab. 6.4 Switch contacts
INFO The Home-In contact can be used for external
safety devices (e.g. window contact switches).
If the switch is open, the cooktop extractor is
out of operation.
Ensure that the universal control unit is disconnected
from the power supply.
Preparing the universal control unit
Remove the screws from the universal control unit.
Lift up the cover.
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bora PL540E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bora PL540E in the language / languages: English as an attachment in your email.

The manual is 3,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bora PL540E

Bora PL540E User Manual - German - 36 pages

Bora PL540E User Manual - Dutch - 36 pages

Bora PL540E User Manual - French - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info