100.0 µF 110.0 µF 0.1 µF ± (1.9 % of reading + 5 digits)
1.000 mF 1.100 mF 0.001 mF ± (1.9 % of reading + 5 digits)
10.00 mF 11.00 mF 0.01 mF ± (1.9 % of reading + 5 digits)
7.10
Frequency ranges
Overload protection: 1000 V
AC/ DC
Measuring range OL indication Resolution Measurement accuracy
100.00 Hz 100.00 Hz 0.01 Hz ± (0.1 % of reading + 5 digits)
1000.0 Hz 1000.0 Hz 0.1 Hz ± (0.1 % of reading + 5 digits)
10.000 kHz 10.000 kHz 0.001 kHz ± (0.1 % of reading + 5 digits)
100.00 kHz 100.00 kHz 0.01 kHz ± (0.1 % of reading + 5 digits)
Minimum frequency: 1 Hz
Minimum sensitivity: > 5 V
eff
for V
AC
(1 Hz - 10 kHz)
> 20 V
eff
for V
AC
(10 kHz - 50 kHz), not specified for (50 kHz
to 100 kHz)
> 0,6 A
eff
for A
AC
7.11 Temperature ranges °C/ °F (BENNING MM 6-1)
Overload protection: 1000 V
AC/ DC
Measuring range OL indication Resolution Measurement accuracy*
-40 °C - +400 °C - 44 °C - +440 °C 0.1 °C ± (1 % of reading + 20 digits)
-40 °F - +752 °F - 44 °F - +827.2 °F 0.1 °F ± (1 % of reading + 36 digits)
* The measuring accuracy of the K-type temperature sensor has to be added
to the specified measuring accuracy.
Wire temperature sensor (type K): Measuring range: - 60 °C to 200 °C
Measurement accuracy: ± 2 °C
The measuring accuracy applies to stable ambient temperatures < ± 1 °C. After
a change of the ambient temperature of ± 2 °C, the measuring accuracy data
will apply after 2 hours.
7.12 PEAK HOLD for AC V/ AC A
Please add ± 150 digits to the specified measuring accuracy.
Square-wave signals are not specified.
8. Measuring with the BENNING MM 6-1/ MM 6-2
8.1 Preparation for measuring
Store and use the BENNING MM 6-1/ MM 6-2 only under the correct tempera-
ture conditions stated. Always avoid longer exposure to sunlight.
- Check the rated voltage and rated current stated on the safety measuring
leads. The safety measuring leads supplied with the unit are suitable for the
rated voltage and current of the BENNING MM 6-1/ MM 6-2.
- Check the insulation of the safety measuring leads. If the insulation is dam-
aged in any way, do not use the leads.
- Check the continuity of the safety measuring leads. If the conductor in the
safety measuring lead is interrupted, do not use the leads.
- Before selecting another function with the rotating switch
, always discon-
nect the safety measuring leads from the measuring point.
- Sources of strong current in the vicinity of the BENNING MM 6-1/ MM 6-2
may cause unstable or incorrect readings.
8.2 Voltage and current measurement
Always observe the maximum voltage to earth potential!
Electrical hazard!
The maximum voltage which may be applied to the sockets
- COM socket
- socket (+) for V, Ω, , Hz, μA, (BENNING MM 6-1) or for V, Ω, , Hz
(BENNING MM 6-2)
- socket for 10 A range
L
(BENNING MM 6-2)
of the BENNING MM 6-1/ MM 6-2 to earth is 1000 V CAT III.
8.2.1 Voltage measurement
- With the rotating switch
, select the desired function ( , , ) on the
BENNING MM 6-1/ MM 6-2.
- Connect the black safety measuring lead to the COM socket
on the
BENNING MM 6-1/ MM 6-2.
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Benning MM6.2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Benning MM6.2 in the language / languages: English, German, Dutch, French, Italian, Polish, Turkish, Spanish as an attachment in your email.

The manual is 2,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info