692253
27
Zoom out
Zoom in
Previous page
1/56
Next page
02/ 2016
BENNING MM 6-1/ 6-2
27
- Connect the red safety measuring lead to the socket
on the
BENNING MM 6-1/ MM 6-2.
- Connect the safety measuring leads to the measuring points. Read the measure-
ment value displayed in the digital display
of the BENNING MM 6-1/ MM 6-2.
See fig. 2: DC-voltage measurement
See fig. 3: AC-voltage measurement
8.2.2 Current measurement
- With the rotating switch
, select the desired range and function (A AC/DC
or µA AC/DC) on the BENNING MM 6-1/ MM 6-2.
-
Connect the black safety measuring lead to the COM socket
on the
BENNING MM 6-1/ MM 6-2
.
- Connect the red safety measuring lead to the jack for the A range
L
(up to
10 A AC/DC) of the BENNING MM 6-2 or to the jack for V, Ω, Hz, μA AC/DC,
,
(up to 600 μA DC) of the BENNING MM 6-1.
- In the ( ) function, select the current type to be measured – direct cur-
rent (DC) or alternating current (AC) – by pressing the key (blue)
4
of the
BENNING MM 6-1.
- Connect the safety measuring leads to the measuring points. Read
the measurement value displayed in the digital display
of the
BENNING MM 6-1/ MM 6-2.
See fig. 4: DC-current measurement
See fig. 5: AC-current measurement
8.3 Resistance measurement
- With the rotating switch
, select the desired function (Ω, ) on the
BENNING MM 6-1/ MM 6-2.
- Connect the black safety measuring lead to the COM socket
on the
BENNING MM 6-1/ MM 6-2.
- Connect the red safety measuring lead to the socket
on the
BENNING MM 6-1/ MM 6-2.
- Connect the safety measuring leads to the measuring points. Read the measure-
ment value displayed in the digital display
of the BENNING MM 6-1/ MM 6-2.
See fig. 6: Resistance measurement
8.4 Diode testing
- With the rotating switch
, select the desired function ( ,
) on the
BENNING MM 6-1/ MM 6-2.
- Using the blue key
on the BENNING MM 6-1/ MM 6-2, switch to diode
testing ( ).
- Connect the black safety measuring lead to the COM socket
on the
BENNING MM 6-1/ MM 6-2.
- Connect the red safety measuring lead to the socket
on the
BENNING MM 6-1/ MM 6-2.
- Contact the diode connections with the safety measuring leads and
read the measurement value displayed in the digital display
of the
BENNING MM 6-1/ MM 6-2.
- For a normal silicone diode located in flow direction, the flow voltage
between 0.4 V and 0.8 V is displayed. If “000” appears in the display, there
may be a short circuit in the diode.
- If no forward voltage is detected, first check the polarity of the diode. If still
no forward voltage is displayed, the forward voltage of the diode is beyond
the measuring limits.
See fig. 7: Diode testing
8.5 Continuity testing with buzzer and red LED
- With the rotating switch
, select the desired function (Ω, ) on the
BENNING MM 6-1/ MM 6-2.
- Using the blue key
4
on the BENNING MM 6-1/ MM 6-2, switch to conti-
nuity testing ( ).
- Connect the black safety measuring lead to the COM socket
on the
BENNING MM 6-1/ MM 6-2.
- Connect the red safety measuring lead to the socket
on the
BENNING MM 6-1/ MM 6-2.
- Contact the measuring points with the safety measuring leads. If the line
resistance between the COM jack
and the jack
falls below 20 to
200 Ω, the integrated buzzer of the BENNING MM 6-1/ MM 6-2 sounds and
the red LED
N
lights up.
See fig. 8: Continuity testing with buzzer
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Benning MM6.2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Benning MM6.2 in the language / languages: English, German, Dutch, French, Italian, Polish, Turkish, Spanish as an attachment in your email.

The manual is 2,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info