692253
24
Zoom out
Zoom in
Previous page
1/56
Next page
02/ 2016
BENNING MM 6-1/ 6-2
24
must be removed from the unit.
7. Electrical data
Note: The measurement accuracy is stated as the sum of
- a relative proportion of the measurement value and
- a number of digits (i.e. numerical steps of the last place).
This measurement accuracy applies for a temperature of 18 °C to 28 °C and a
maximum relative humidity of max. 80 %.
The measurement value is obtained as a true RMS value (AC coupling) and
displayed as such. Square-wave signals are not specified. With non-sinusoidal
curves, the value displayed is less accurate. This results in an additional error
for the following crest factors:
Crest factor of 1.0 to 2.0, additional error + 3.0 %.
Crest factor of 2.0 to 2.5, additional error + 5.0 %.
Crest factor of 2.5 to 3.0, additional error + 7.0 % (applies to up to 4000 digits).
7.1 DC voltage ranges
The input resistance is 10 MΩ
Overload protection: 1000 V
AC/DC
Measuring range OL indication Resolution Measurement accuracy
6.000 V 6.600 V 0.001 V ± (0.5 % of reading + 5 digits)
60.00 V 66.00 V 0.01 V ± (0.5 % of reading + 5 digits)
600.0 V 660.0 V 0.1 V ± (0.5 % of reading + 5 digits)
7.1.1 DC voltage ranges mV DC
The input resistance is 10
Overload protection: 1000 V
AC/DC
Measuring range OL indication Resolution Measurement accuracy
600.0 mV 660.0 mV 0.1 mV ± (0.5 % of reading + 8 digits)
7.2 AC voltage ranges
The input resistance is 10 MΩ parallel < 100 pF.
Overload protection: 1000 V
AC/DC
Measuring
range
OL indication Resolution
Measurement accuracy
in frequency range 45 Hz - 500 Hz (sine)
600.0 mV 660.0 mV 0.1 mV ± (1.0 % of reading + 8 digits)*
6.000 V 6.600 V 0.001 V ± (1.0 % of reading + 5 digits)
60.00 V 66.00 V 0.01 V ± (1.0 % of reading + 5 digits)
600.0 V 660.0 V 0.1 V ± (1.0 % of reading + 5 digits)
* Measuring range from 1.0 mV
7.3 AutoV, “LoZ” range
The low-impedance input resistance of approx. 3 kΩ serves to suppress induc-
tive and capacitive voltages.
Overload protection: 1000 V
AC/DC
Measuring
range
OL indication Resolution
Measurement accuracy
in frequency range 45 Hz - 500 Hz (sine)
600.0 V 660.0 V 100 mV ± (2.0 % of reading + 5 digits)*
1000 V 1100 V 1 V ± (2.0 % of reading + 5 digits)
* Measuring range from ≥ 1.0 mV
7.4 DC current ranges (BENNING MM 6-2)
Overload protection:
- 11 A (1000 V AC/ DC) fuse, 20 kA, rapid on 10 A input
Max. measuring time:
- 3 minutes at > 5 A (pause > 20 minutes)
- 30 secondes at > 10 A (pause > 10 minutes)
Measuring range OL indication Resolution Measurement accuracy
6.000 A 6.600 A 0.001 A ± (1.0 % of reading + 5 digits)
10.00 A 20.00 A 0.01 A ± (1.0 % of reading + 5 digits)
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Benning MM6.2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Benning MM6.2 in the language / languages: English, German, Dutch, French, Italian, Polish, Turkish, Spanish as an attachment in your email.

The manual is 2,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info