Id.Nr.: 123158-19
ELECTRICAL CONNECTION
General notes
a) The electrical connection must always be made according to the wiring diagram glued in the terminal
compartment of the storage tank and may only be carried out by a licensed specialist!
b) The specications on the specication label must always be observed (voltage, type of current, power
and heating time).
c) An all-pole circuit breaker with a 3 mm contact opening width must be installed in the electrical supply
line. Automatic circuit breakers are also permissible as switching devices.
d) The connection cable is fed into the connection area of the tank through the cable feed-through collar
(behind the water connection pipes on the underside of the tank) and then secured via the strain-relief
mechanism.
e) The cover on the lower right side of the device must be removed in order to wire the connection cable
to the connection terminals.
f) The tank must be completely disconnected from all poles of the power supply according to EN 50110
(ÖVE, TAEV) before starting any installation work or other intervention.
The unit must be secured against switching on of the supply voltage (remove fuses, switch o circuit breaker)
before performing any further work.
Rewiring possibilities
With tanks allowing a selectable heating time, the heating rods must be rewired according to the wiring
diagram glued inside the device. The factory wiring corresponds to a 6-hour heating time using a ~ 230 V
connection voltage. The 3 ~ 400 V or 3 N ~ 400 V three-phase wiring possible with 100 litre devices and
upwards must also be rewired on site according to the following table. Switchable heating times, power
and associated fuse currents. Bold values represent the factory settings (6 hrs. 230 V).
Switchable device Heating time at supply voltage
~230V 3~400V 3N~400V
Heating element Wiring* S S+M S+S S+M+S S+M+S in star wiring
Heat-up time in hours 8 6 4 31/3 4 31/3 31/3
EKF 070 U
tank capacity 70 l
kW
A
0,85
6
1,15
6
1,7
10
2,0
10
EKF100 U
tank capacity 100 l
kW
A
1,1
6
1,75
10
2,2
10
2,85
16
2,8
6
EKF120 U
tank capacity 120 l
kW
A
1,35
10
2,0
10
2,7
16
3,35
16
3,2
6
EKF150 U
tank capacity 150 l
kW
A
1,65
10
2,3
16
3,3
16
3,7
10
3,95
10
* S = side heating element in heating ange
M = middle heating element in heating ange
The special model EKF 123 D is equipped as standard with a heating power of 3.3 kW and a supply vol-
tage of 3~400 V at 31/3 hours heating time.
This device cannot be switched to a dierent power.
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Austria Email EKF series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Austria Email EKF series in the language / languages: English, German as an attachment in your email.

The manual is 0.7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info