The following must always be observed:
To ensure correct operation of the connection tting this must only be installed in frost-free rooms. The
safety valve outlet must be open and able to be examined and the outlet pipe from the drip catcher (ex-
pansion water funnel) must not lead directly outside so that malfunctions cannot be caused by frost or
clogging through soiling. Care must be taken to ensure that the drip cup is not clogged.
Care must also be taken to ensure that the safety valve outlet pipe is installed at a constant downwards
inclination.
No shut-o valve or other restriction device may be installed between the safety valve and the cold water
inlet of the tank. The safety valve must be set to actuate at a pressure less than the rated pressure of the
tank (6 bar). The cold water supply pipe must be ushed before nal connection of the tank. The dischar-
ge openings of the safety valves (domestic water and heating circuits) must open out into an appropriate
drainage object in order to avoid any damage caused by the escape of operating uid.
The connection tting must be checked for correct operation after the water supply has been connected
and the tank has been lled, free of air bubbles.
a) To avoid blocking of the safety valve venting mechanism due to limescale, the safety valve venting
mechanism should be manually actuated from time to time while the system is in operation. The valve
must close once more when the venting mechanism is released and the vented water must ow com-
pletely out of the funnel or venting pipe.
b) In the case of safety valves installed before water heaters, the safety valve must actuate when the water
heater is heating up. This can be seen though water escaping from the venting line.
To be performed by: Operator, installation company
Interval: Every 6 months
Maintenance and repairs:
If water does not escape when hot water is being heated, or the safety valve leaks permanently, then an
attempt should be made to release the valve or ush any foreign bodies (e.g. calcium carbonate particles)
from the valve seal, via multiple actuation of the venting mechanism.
If this does not succeed, then an authorised installation company must repair the system. In the case of
damage to the valve seat or seal, the safety valve must be completely replaced.
To be performed by: Installation company
Interval: Annually
To check the backow valve the shut-o valve is closed and then no water should ow out of the open
test valve.
The tank is operated vie the hot water valve of the outlet tap (mixing taps). The tank is therefore per-
manently under pipe pressure. To protect the internal boiler against overpressure when heating up, the
expansion water created is dispersed through the safety valve. Calcied safety valves must always be
replaced to avoid overpressure damage to the hot water heater. In the case of a loss of supply pressure,
the backow valve prevents hot water from owing into the cold water piping network and thus protects
the boiler from being heated without water. The shut-o valve allows the tank to be disconnected from
the water supply and thus also from the cold water pipe pressure, which allows it to be drained via the
drainage valve.
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Austria Email EKF series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Austria Email EKF series in the language / languages: English, German as an attachment in your email.

The manual is 0.7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info