810510
13
Zoom out
Zoom in
Previous page
1/100
Next page
12
EN
ATTENTION: If is not installed in the system equipment against condensation, or the
equipment will not operate properly, can result in the formation of aggressive conden-
sate. It lead to boiler damage. Protection against condensation must be used during
operation of the boiler, otherwise it will void warranty by the manufacturer!
2.4.3 CHIMNEY
Connection of the appliance to the chimney hole must be always done with permission of the
appropriate chimney sweep association. The chimney must generate sufficient draught and take
the flue gas out into the atmosphere under the all operating conditions.
Correct dimensions of the chimney hole are important the correct boiler function, because the
burning, output and boiler life–time are influenced by the draught. The chimney draught direct-
ly depends on its diameter, height and roughness of the internal wall. It is not allowed to con-
nect any other appliance to the chimney, where the boiler is connected. Diameter of the chim-
ney must not be smaller than the connection part on the boiler. The chimney draught must
achieve the prescribed values, but it cannot be too high, not to decrease the boiler output and
interrupt the burning (flame). If there is too strong draught, install the throttle flap into the
chimney hole between the boiler and the chimney.
Prescribed dimensions of the chimney section:
20×20 cm min. height 7 m
20 cm min. height 8 m
15×15 cm min. height 11 m
16 cm min. height 12 m
The exact chimney dimension is defined by the STN 73 42 10. The prescribed chimney draught is
given in the Technical parameters.
2.4.4 FLUE GAS CONNECTION
The flue connection must lead into the chimney hole. If it is not possible to connect the boiler to
the chimney hole directly, then the appropriate extension should be as short as possible, of up
to 1 m length, without any additional heating area and it should ascend in direction to the
chimney. The flue connection must be mechanically tight (it should be mounted to the boiler
and tightly fixed by screws) and tight against the flue leakage. The flue connections must to lead
through the foreign dwelling or commercial premises. The internal diameter of the flue connec-
tion must not taper in direction to the chimney. It is not suitable to use the elbow connectors.
Flue must be connected to a chimney T–shaped to drop condensate from the chimney into an
aimed container and not to the boiler.
2.4.5 BOILER CONNECTION TO THE ELECTRICITY MAINS
The boiler is connected to the electricity mains of 230 V/50 Hz/16 A by an electrical cord with
plug. In the case of need, the power supply cord of the M type must be replaced with an ade-
quate one by the service organization. The appliance must be placed in the way enabling to
reach the connection plug. The boiler must be connected to the 16 A socket circuit by a circuit
breaker (following the STN EN 60 335–1 + A11:1997).
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATTACK DPX Combi Pellet at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATTACK DPX Combi Pellet in the language / languages: English as an attachment in your email.

The manual is 8.73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info