810510
15
Zoom out
Zoom in
Previous page
1/100
Next page
14
EN
2.4.7 BURNER CONNECTION TO THE BOILER AND BOILER TEMPERATURE
SENSOR
Burner is connected to the boil-
er by cable with 6–pin connect-
or that comes from the feet of
the boiler, at the point where
pantograph arm is fixed. The
cable is necessary after assem-
bly to attach to the arm of the
pantograph by supplied plastic
tapes from the bottom of the
pantograph arms in a correct
distance so by manipulation of
the burner to prevent stretching
or strain of the cable. With the
cable is also connected the
boiler temperature sensor to
the arm of the pantograph. The
connector which is the sensor
completed, it is necessary to
connect in connector TS2 in
control electronic of burner.
2.4.8 CHOICE AND CONNECTION OF THE CONTROL AND REGULATION COM-
PONENTS
The boiler is delivered with the basic regulation and control equipment. These should be sup-
plemented by elements that are not part of the boiler delivery but must be installed in the heat-
ing circuit. They are mainly a safety valve (picture 4) against exceeding the allowable pressure in
the heating system (priecribe 2.5 bar), the valve of aftercooling circuit of the boiler to abduce
surplus heat from the boiler to the drain and vent valve for proper operation of the boiler. The
expansion tank in the system must have sufficient volume to be fixed by designer of heating
system under current regulations. Electric installation with the additional equipment of the boil-
er must be done by a specialist according to the current standards.
WARNING! The heating system must be equipped with
a safety valve against overpressure (2,5 bar). This valve is rec-
ommended to place on riser in front of shut–off valve of the boiler (or
before OVENTROP). If the safety valve will not be working, excess
pressure have nowhere to escape and the boiler may explode!
Safety valve against overpressure
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATTACK DPX Combi Pellet at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATTACK DPX Combi Pellet in the language / languages: English as an attachment in your email.

The manual is 8.73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info