Heat pump water heater – OPERATING AND MAINTENANCE INSTRUCTIONS
45
7.8 Electrical connections "Check" (function activated by the installer menu)
With this function you can control the electrical connections made during installation.
You can start the procedure from the installer menu, setting the parameter C1 ON and confirm by
pressing the knob. The procedure takes about 8 minutes during which the progress symbols flashes
on the display. To stop this procedure press "mode ".
If at the end of the procedure has the response "OK", the electrical connections were made properly.
If the response is "KO " recheck the electrical connections between indoor and outdoor units paying
attention to the numbers indicated on the terminals. Check probes cable.
7.9 Anti-legionnaire’s disease protection (function activated only through the installer menu)
If activated, the water heater automatically carries out the anti
-
legionnaire’s disease protection
function. The water is brought to a temperature of 65 °C on a monthly basis and for a maximum time
of 15 minutes, so as to avoid germs from developing in the water tank and piping (provided the water
has not been brought to T>57 °C at least once for at least 15 minutes). The first heating cycle is
performed 3 days after the function has been activated. As these temperatures may cause burns, it is
advisable to use a thermostatic mixer.
The achievement of temperatures above the set is marked with the symbol of the waves.
During the cycle of antilegionella will be displayed “ANTI_B” alternately to the mode of operation,
once the cycle is done the set temperature remains the original one.
In the event that is enabled the two-tier rate signal HC-HP, the function will take place during the
economic tariff. To stop press "on/off".
7.10 Default settings
The appliance is manufactured with a series of default modes, functions or values, as indicated in the table below:
Parameter
Factory default setting
AUTO MODE ACTIVATED
BOOST MODE ACTIVATED
PRE-SET TEMPERATURE 55 °C
P1 MAX. TEMPERATURE SETTABLE WITH THE HEATING ELEMENT 65 °C
P2 MINIMUM SETTABLE TEMPERATURE 50 °C
P3 MAX. TEMPERATURE SETTABLE WITH THE HEAT PUMP 55 °C
P4 GREEN MODE ACTIVATED
P5 ANTI-LEGIONNAIRE’S DISEASE PROTECTION DEACTIVATED
P6 VOYAGE MODE DEACTIVATED
P7 DEFROST (active defrost activation) ACTIVATED
P8 HC-HP (two-tier rate operation mode) DEACTIVATED
P9 TIME_W (no. of accepted hours of powering) 8 h
P11
PROGRAM MODE (P1, P2, P1+P2) DEACTIVATED
PROGRAM P1 TEMPERATURE PRESET 55 °C
PROGRAM P1 TIME PRESET 06:00
PROGRAM P2 TEMPERATURE PRESET 55 °C
PROGRAM P2 TIME PRESET 18:00
P12
BOOST2 MODE DEACTIVATED
7.11 Operation with two-tier electricity rate
To be able to operate also on appliances with a two-tier rate system, the control logic calculates the number of
average hours a day during which the power supply is available in the economy mode (HC).
A self-learning function ensures that the appliance reaches the pre-set temperature in the time range during which the
economy rate applies; the maximum limit of hours is determined by the P9 TIME_W parameter; after the initial start-up
(or after switching off the hardware), the default setting is 8 hours.
45


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston NUOS 200 SPLIT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston NUOS 200 SPLIT in the language / languages: English, Dutch, French, Italian as an attachment in your email.

The manual is 2,77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info