Heat pump water heater – OPERATING AND MAINTENANCE INSTRUCTIONS
47
8. MAINTENANCE (for authorized personnel)
WARNING! Obse
rve the general warnings and safety instructions listed in the previous paragraphs and
strictly adhere to the indications therein contained.
All maintenance operations and interventions should be performed by qualified personnel (i.e. with the
necessary requirements as outlined in the applicable norms in force).
8.1 Draining the appliance
The appliance must be drained if left inactive in a room subject to frost.
When necessary, empty the appliance as follows:
- Disconnect the appliance from the mains.
- Close the shut-off valve, if installed, or the central tap of the domestic water supply network.
- Open the hot water tap (washbasin or bathtub).
- Open the tap located on the safety valve.
8.2 Routine maintenance
It is advisable to clean the evaporator on an annual basis in order to remove any dust or obstructions.
To access the evaporator, placed on the external unit, it is necessary to remove the fixing screws of the grid casing;
clean the evaporator with a flexible brush taking care not damage it. In the case you found some bended fins,
straighten them with a special comb, according to the fins spacing (1.6 mm).
Still on external unit, ensure that the condensate water runs out in a suitable drain and make sure the discharge is
made without hindrance.
Use only original spare parts.
8.3 Troubleshooting
Problem
Possib
le
reason
What to do
Water comes
out cold or
insufficiently
warm
Low temperature set
Increase the temperature set for the outlet water
Device functioning errors
Check for errors on the display an
d act in the wa
y specified on the
chart "Faults"
No electrical connection, disconnected or
damaged wirings
Check the voltage at the supply terminals, verify the integrity and
connections of the cables.
Absence of HC/HP signal (if the product is
installed with the HC/HP signal cable)
Try to put the product in “Boost” mode, if is ok in this way, check the
connection of the meter, check the integrity of the HC/HP cable.
Malfunctioning of the timer for two
-
tier rate (if the
product is installed in this configuration)
Check the operation of the contactor day / night and that the set
time is enough to heat water
Funcioning in “Voyage” mode
verify is not the programming period "Voyage", in that case
deactivate the function
Product off Check availability of electricity, turn on the product
Usage of a large amount of hot water when the
product is heating up phase
Probe error
Control the presence, even if occasional E5
The water is
boiling (with the
possible
presence of
steam from the
taps)
High level of scaling of the boiler and
components
Turn off the power, drain the unit, remove the sheath of the
resistance and remove lime scale inside the boiler, be careful not to
damage the enamel of the boiler and the sheath resistance.
Repackage the product as in the original configuration, it is
recommended to replace the flange gasket.
Probe error
Control the presence, even if occasional E5
Reduced
functioning of
the heat pump,
semi-
permanent
operation of the
electrical
resistance
Air temperature out of rang
e
Depending from the climatic conditions
“Time W” value too low
Set a parameter for lower
temperature or a
longer
unit of
“Time W
"
Installati
on done not in accordance with e
lectric
voltage (too low)
Provide a proper Electric voltage
Evaporator clogge
d or frozen
Check the cleaning
of the evaporator
Problems with the heat pump circuit
Make sure that there are no errors on the display
Are not yet past 8 days by:
-First Time instalation.
-change of the parameter Time-W.
-No power from mains in absence of batteries
or exhausted batteries.
P7 parameter set to OFF and out
side air
temperature below 10 °C
Set parameter P7 ON
47


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston NUOS 200 SPLIT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston NUOS 200 SPLIT in the language / languages: English, Dutch, French, Italian as an attachment in your email.

The manual is 2,77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info