Heat pump water heater – OPERATING AND MAINTENANCE INSTRUCTIONS
46
7.12 Anti-frost function
In any event, if the temperature of the water in the tank falls below 5 °C while the appliance is powered, the heating
element (1000 W) will be automatically activated to heat the water up to 16 °C.
7.13 Faults
As soon as a fault occurs, the appliance enters into the fault mode while the display emits flashing signals and
visualises the error code. The water heater will continue supplying hot water provided the fault affects only one of two
the heating units, by activating the heat pump or heating element.
If the fault involves the heat pump, the symbol "HP" will flash on the screen, while the heating element symbol will
flash if the fault involves this component. If both components are affected, both symbols will flash.
Error
code
Cause
Heating
element
operation
Heat pump
operation
What to do
E1
Heating occurs without any water in
the water tank
OFF OFF
Turn off the appliance. Verify the causes of the lack of water
(leakage, faulty hydraulic connections, etc.)
E2
Excessive temperature of the water
in the tank
OFF OFF
Turn the
appliance off then wait until the water temperature
decreases; if the problem persists, contact the technical assistance
service
E4 Sensor fault – heating element zone OFF OFF Check or replace the heating element zone sensors, if necessary
E5
Excessive
difference between the
temperatures of the heating
element zone sensors
OFF OFF Check or replace the sensors, if necessary
H2 Circuit in low pressure or fan fault ON OFF
Turn off the appliance
.
Check that the fan is not broken and that
the evaporator is not obstructed. Check whether the hot gas valve
functions properly and replace it if necessary. Check the
evaporator sensor.
H3 Compressor fault or gas leak ON OFF
Turn off the appliance. Check that the evaporator is not obstructed.
Verify whether the wirings and the compressor functions properly
and/or check for any refrigerant gas leakages. Check or replace
the evaporator sensor.
H4 Evaporator obstructed ON ON
Turn off the appliance. Check that the evaporator and the external
unit casing is not obstructed.
H5 Fan fault ON OFF
Turn off the appliance. Verify that there are no physical
impediments to the movement of fan blades, check the wiring of
connection with circuit boards. Check the evaporator sensor.
H6 Air sensor fault ON OFF
Check the proper co
nnection of the probe cable between the two
units, Verify whether the sensor is properly connected and
positioned, and replace it if necessary.
H7 Evaporator sensor fault ON OFF
Check the proper connection of the probe cable between the two
units, Verify whether the sensor is properly connected and
positioned, and replace it if necessary.
H8 Hot water sensor fault ON OFF
Verify whether the sensor is properly connected and positioned,
and replace it if necessary
H9 Active defrost fault ON
OFF
(if air
temperature
il below
5°C)
Check that the fan is not broken and that the evaporator is not
obstructed. Check whether the hot gas valve functions properly
and replace it if necessary. Check that the external unit casing is
not obstructed.
F1 PCB fault OFF OFF
Try turning the appliance off then on again and verify the operation
of the control boards, if necessary replace it.
F2
Excessive number of
ON/OFF
(RELEASE)
OFF OFF Temporarily disconnect the product mains and the batteries.
F3
Lack of communication betw
een the
PCB and interface
OFF OFF
Try turning the appliance off then on again and verify the operation
of the control boards or replace them, if necessary.
F4
Empty tank (EMPTY), impressed
current anode circuit open
OFF OFF
Verify whether there is any wat
er in the tank, check or replace the
impressed current anode, if necessary.
F5
Short
-
circuit on the impressed
current anode circuit
ON ON Check or replace the impressed current anode if necessary
46


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston NUOS 200 SPLIT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston NUOS 200 SPLIT in the language / languages: English, Dutch, French, Italian as an attachment in your email.

The manual is 2,77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info