Earthing
The connection to earth (ground) in an audio system is important for two reasons:
1.
SAFETY - To protect the operator from high voltage shock, and
2.
AUDIO PERFORMANCE - To minimise the effect of earth (ground) loops
which result in audible hum and buzz, and to shield the audio signals from interference.
For safety it is important that all equipment earths are connected to mains earth so that
exposed metal parts are prevented from carrying high voltage which can injure or even
kill the operator. It is recommended that the engineer check the continuity of the safety
earth from all points in the system including microphone bodies, guitar strings,
connector cases, equipment panels and so on.
The same earth is also used to shield audio cables from external interference such as
the hum fields associated with power transformers, lighting dimmer buzz, and computer
radiation. Problems arise when the signal sees more than one path to mains earth. An
earth loop results causing current to flow between the different earth paths. This
condition is usually detected as a mains frequency audible hum or buzz.
To ensure safe and trouble-free operation we recommend the following:
Use a clean mains outlet for the audio system. Keep the audio
equipment mains feed separate from that powering ‘dirty’ equipment such as air
conditioning and lighting systems, motors and vending machines.
Use star point earthing. It is best to install a ‘star point’ system where the
individual earths to the equipment racks and equipment areas are separately run from a
solid central reference earth point.
Have your mains system checked by a qualified electrician. If the
supply earthing is solid to start with you are less likely to experience problems.
Do not remove the earth connection from the console mains plug.
The console chassis is connected to mains earth through the power cable to ensure
your safety. Audio 0V is connected to the console chassis internally. If problems are
encountered with earth loops operate the audio ‘ground lift’ switch on the power supply
or connected equipment, or disconnect the cable screens at one end, usually at the
destination.
Avoid induced interference. To prevent interference pickup keep audio cables
away from mains power units, cables and distribution boards, motors, lighting and
computer cables and equipment, and any other heavy duty electrical equipment. Where
this cannot be avoided cross the audio and ‘dirty’ equipment cables at right angles to
minimise interference.
Use low impedance sources such as microphones and line level equipment
rated at 200 ohms or less to reduce susceptibility to interference. The console outputs
are designed to operate at very low impedance to minimise interference problems.
Use balanced connections where possible as these provide further
immunity by cancelling out interference that may be picked up on long cable runs. To
connect an unbalanced source to a balanced console input, link the cold input (XLR pin
3 or jack ring) to 0V earth (XLR pin 1 or jack sleeve) at the console. To connect a
balanced console output to an unbalanced destination, link the cold output to 0V earth at
the console.
Use good quality cables and connectors and check for correct wiring and
reliable solder joints. Allow sufficient cable loop to prevent damage through stretching.
If you are not sure ... Contact your service or local Allen & Heath agent for advice.
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Allen-Heath ML 3000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Allen-Heath ML 3000 in the language / languages: English as an attachment in your email.

The manual is 3,51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info