<14. EXPLOSION PROTECTED TYPE INSTRUMENT>
14-12
IM 01F06A00-01EN
14.4 CSA
(1) Technical Data
• Explosion Proof
Applicable Standard: C22.1-98, C22.2 No.0-M1991,
C22.2 No.0.4-04, C22.2
No.0.5-1982, C22.2 No. 25-
1966, C22.2 No. 30-M1986,
C22.2 No. 94-M1991, C22.2
No. 142-M1987, C22.2 No.
61010-1-04, ANSI/ISA-
12.27.01-2003
Certi cate: 1166201
Type of Protection:
Explosionproof for Class I, B, C and D; Class II,
Groups E, F and G; Class III.
For Class I, Division 2 location:
“FACTORY SEALED, CONDUIT SEAL NOT
REQUIRED.”
Enclosure : Type 4X
(Integral Type Vortex Flowmeter and Remote Type
Vortex Flow Detector)
Temperature Code
Ambient
Temperature
Process
Temperature
T6 60°C 85°C
T5 60°C 100°C
T4 60°C 135°C
T3 60°C 200°C
T2 60°C 300°C
T1 60°C 450°C
Temperature Code: T6 (Remote Type Vortex Flow
Converter)
Ambient Temperature:
-29 to +60°C (Integral Type Vortex Flowmeter
and Remote Type Vortex Flow Detector)
-40 to +60°C (Remote Type Vortex Flow
Converter)
Power Supply: 42Vdc max. (Integral Type Vortex
Flowmeter and Remote Type Vortex
Flow Converter)
Output Supply (Integral Type Vortex Flowmeter):
Current Output; 4 to 20mAdc
Pulse Output; On=2Vdc, 200mA
Off=42Vdc, 4mA
Output Signal (Remote Type Vortex Flow Detector):
Output Signal; 30Vp-p, 100Ap-p
Input/Output signal (Remote Type Vortex Flow
Converter): Current Output; 4 to 20mAdc
Pulse; On=2Vdc, 20mA
Off=42Vdc, 4mA
Input Signal; 30Vp-p, 100Ap-p
Electrical Connection: ANSI 1/2 female (Special)
• Intrinsically Safe
Type “n” and Non-incendive
Applicable Standard: C22.2 No. 0-M91, C22.2
No. 0.4-2004, C22.2 No.
157-M1987, C22.2 No. 213-
M1987, C22.2 No. 1010.1-92,
CAN/CSA-E60079-0:02,
CAN/CSA-E60079-11:02,
CAN/CSA-E60079-15:02,
ANSI/ ISA-12.27.01-2003
Certi cate: 1198227
Type of Protection:
Ex ia IIC T4...T1 and Ex nC IIC T4...T1
(Integral Type Vortex Flowmeter and Remote
Type Vortex Flow Detector)
Ex ia IIC T4 and Ex nC IIC T4
(Remote Type Vortex Flow Converter)
(Integral Type Flowmeter and Remote Type Vortex
Flow Detector)
Temperature Code
Ambient
Temperature
Process
Temperature
T4 60°C 135°C
T3 60°C 200°C
T2 60°C 300°C
T1 60°C 450°C
Ambient Temperature:
-29 to +60°C (Integral Type Vortex Flowmeter and
Remote Type Vortex Flow Detector)
-40 to +60°C (Remote Type Vortex Flow
Converter)
Degree of Protection of Enclosure: IP67
Electrical Parameters: Ui=30Vdc, Ii=165mAdc,
Pi=0.9W
Ci=12nF, Li=0.15mH
Electrical Connection: ANSI 1/2 NPT female
Type of Protection:
Intrinsically Safe for Class I,II,III, Div.1, Groups
A,B,C,D,E,F and G, Non- incendive for Class I,II,
Div.2, Groups A,B,C,D,E,F and G, Class III, Div.1
(Integral Type Vortex Flowmeter and Remote Type
Vortex Flow Detector)
Temperature Code
Ambient
Temperature
Process
Temperature
T4 60°C 135°C
T3 60°C 200°C
T2 60°C 300°C
T1 60°C 450°C
Temperature Code: T4 (Remote Type Vortex Flow
Converter)
Ambient Temperature: -40 to 60°C
Enclosure: Type 4X
Electrical Parameters:
Vmax=30Vdc,
Imax=165mAdc, Pmax=0.9W,
Ci=12nF, Li=0.15mH
163


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yokogawa DYA Vortex Flow Converter at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yokogawa DYA Vortex Flow Converter in the language / languages: English as an attachment in your email.

The manual is 5,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info