Page 144 FT DX 9000MP OPERATION MANUAL
MENU MODE
102. SUB-RTTY-SLOPE
Function: Selects the shape factor of the sub band
(VFO-B) DSP filter for the RTTY mode.
Available Values: GENTLE/MEDIUM/STEEP
Default Setting: MEDIUM
103. SUB-RTTY-NARROW
Function: Selects the passband of the sub band (VFO-
B) DSP filter for the RTTY “narrow” mode.
Available Values: 25/50/100/200/300/400 Hz
Default Setting: 300 Hz
104. SUB-SSB-SHAPE
Function: Selects the passband characteristics of the
sub band (VFO-B) DSP filter for the SSB mode.
Available Values: SOFT/SHARP
Default Setting: SHARP
SOFT: Primary importance attached to amplitude
of the filter factor.
SHARP: Primary importance attached to phase of the
filter factor.
105. SUB-SSB-SLOPE
Function: Selects the shape factor of the sub band
(VFO-B) DSP filter for the SSB mode.
Available Values: GENTLE/MEDIUM/STEEP
Default Setting: MEDIUM
106. SUB-SSB-NARROW
Function: Selects the passband of the main band
(VFO-A) DSP filter for the “narrow” SSB mode.
Available Values: 200/400/600/850/1100/1350/1500/
1650/1800/1950/2100/2250 Hz
Default Setting: 1800 Hz
SCOPE GROUP
107. MAIN FIX 1.8 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the main
band (VFO-A) 160 m amateur band.
Available Values: 1.800 - 1.999 MHz (1 kHz steps)
Default Setting: 1.800 MHz
108. MAIN FIX 3.5 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 80 m
amateur band.
Available Values: 3.500 - 3.999 MHz (1 kHz steps)
Default Setting: 3.500 MHz
109. MAIN FIX 5.0 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 60 m
amateur band.
Available Values: 5.250 - 5.499 MHz (1 kHz steps)
Default Setting: 5.250 MHz
110. MAIN FIX 7.0 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 40 m
amateur band.
Available Values: 7.000 - 7.299 MHz (1 kHz steps)
Default Setting: 7.000 MHz
111. MAIN FIX 10 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 30 m
amateur band.
Available Values: 10.100 - 10.149 MHz (1 kHz steps)
Default Setting: 10.100 MHz
112. MAIN FIX 14 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 20 m
amateur band.
Available Values: 14.000 - 14.349 MHz (1 kHz steps)
Default Setting: 14.000 MHz
113. MAIN FIX 18 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 17 m
amateur band.
Available Values: 18.000 - 18.199 MHz (1 kHz steps)
Default Setting: 18.068 MHz
114. MAIN FIX 21 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 15 m
amateur band.
Available Values: 21.000 - 21.449 MHz (1 kHz steps)
Default Setting: 21.000 MHz
RX DSP GROUP
146


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yaesu FT-DX9000MP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yaesu FT-DX9000MP in the language / languages: English as an attachment in your email.

The manual is 11,89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info