Page 145FT DX 9000MP OPERATION MANUAL
MENU MODE
115. MAIN FIX 24 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 12 m
amateur band.
Available Values: 24.800 - 24.989 MHz (1 kHz steps)
Default Setting: 24.890 MHz
116. MAIN FIX 28 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 10 m
amateur band.
Available Values: 28.000 - 28.699 MHz (1 kHz steps)
Default Setting: 28.000 MHz
117. MAIN FIX 50 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 6 m
amateur band.
Available Values: 50.000 - 53.999 MHz (1 kHz steps)
Default Setting: 50.000 MHz
118. SUB FIX 1.8 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the main
band (VFO-A) 160 m amateur band.
Available Values: 1.800 - 1.999 MHz (1 kHz steps)
Default Setting: 1.800 MHz
119. SUB FIX 3.5 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 80 m
amateur band.
Available Values: 3.500 - 3.999 MHz (1 kHz steps)
Default Setting: 3.500 MHz
120. SUB FIX 5.0 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 60 m
amateur band.
Available Values: 5.250 - 5.499 MHz (1 kHz steps)
Default Setting: 5.250 MHz
121. SUB FIX 7.0 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 40 m
amateur band.
Available Values: 7.000 - 7.299 MHz (1 kHz steps)
Default Setting: 7.000 MHz
122. SUB FIX 10 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 30 m
amateur band.
Available Values: 10.100 - 10.149 MHz (1 kHz steps)
Default Setting: 10.100 MHz
SCOPE GROUP
123. SUB FIX 14 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 20 m
amateur band.
Available Values: 14.000 - 14.349 MHz (1 kHz steps)
Default Setting: 14.000 MHz
124. SUB FIX 18 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 17 m
amateur band.
Available Values: 18.000 - 18.199 MHz (1 kHz steps)
Default Setting: 18.068 MHz
125. SUB FIX 21 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 15 m
amateur band.
Available Values: 21.000 - 21.449 MHz (1 kHz steps)
Default Setting: 21.000 MHz
126. SUB FIX 24 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 12 m
amateur band.
Available Values: 24.800 - 24.989 MHz (1 kHz steps)
Default Setting: 24.890 MHz
127. SUB FIX 28 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 10 m
amateur band.
Available Values: 28.000 - 28.699 MHz (1 kHz steps)
Default Setting: 28.000 MHz
128. SUB FIX 50 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 6 m
amateur band.
Available Values: 50.000 - 53.999 MHz (1 kHz steps)
Default Setting: 50.000 MHz
147


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yaesu FT-DX9000MP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yaesu FT-DX9000MP in the language / languages: English as an attachment in your email.

The manual is 11,89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info