809256
41
Zoom out
Zoom in
Previous page
1/64
Next page
Commissioning
Greenstar Danesmoor Utility 2022+ and Utility System 2022+ - 6 721 846 263 (2022/01) 41
6.3 Water treatment
Ensure that the system has been cleaned. Refer to section 4.1.2 of
these instructions.
Inhibitor (Central Heating)
Check drain cocks are closed and all radiator valves are open before
adding a suitable inhibitor or combined inhibitor/anti-freeze, if the
system is exposed to freezing conditions, to the heating system
water in accordance with the manufacturers instructions.
Fill system via a WRAS approved filling loop to between 1 and 1.5
bar.
Vent all radiators; tighten vents when complete.
Re-pressurise if necessary to 1bar.
Set all controls to maximum.
Record the date when the inhibitor was added to the system in the
Boiler commissioning checklist and in the guarantee registration.
Water treatment products
Suitable water treatment products can be obtain from the following
manufacturers:
6.4 Starting the appliance
1. Check the oil supply is correctly fitted, pressure tested and in good
working order before turning on the oil supply valves to the boiler.
Turn on the main oil supply valve at the tank and draw off at least
2.5 litres of oil until a steady flow of clear uncontaminated oil can be
seen as follows:
The oil supply to the boiler should be primed before the burner is
operated to avoid unnecessary pump wear.
The use of an oil suction pump will prime and flush through any oil
supply set up simply and easily, alternatively the following
procedures can be used.
6.4.1 Single pipe gravity feed system:
Disconnect the flexible oil hose and open the isolating valve to
discharge the oil into a suitable container.
If a top entry tank has been used the pipework will need to be primed
before the oil will discharge under gravity.
When completed, close the isolating valve, reconnect the flexible oil
hose.
When the oil reaches the pump, bleed the air from the pump:
Open the isolating valve and the oil pump bleed port [1] to discharge
into a suitable container once the boiler is started up.
Switch on the electricity supply to the boiler.
Set the programmer to ON for CH and DHW.
Turn on the boiler CH control thermostat.
Allow the burner to run through to lockout .
Fig. 62
[1] Bleed and pressure gauge port
[2] Vacuum gauge connection
[3] Pressure adjuster
[4] Cover retaining screws x4
If no oil comes out of the port valve [1], then re-prime the oil line as
detailed above
Wait 2 minutes then press the lockout reset button [K].
Repeat the procedure until a steady stream of oil without air, runs
from the bleed port, then lock bleed port [1].
Switch off the boiler.
6.4.2 Double pipe sub-gravity feed systems and single pipe
suction lift with de-aerator:
Prime the oil supply pipework to prevent oil pump damage.
To prime a de-aerator [2], disconnect the flexible oil inlet hose [7]
from the isolation valve and place in a container of heating oil[6].
Connect a spare flexible oil hose [5], to discharge into container [6].
Open the isolating valve, turn on the power to the boiler and set the
programmer to ON. Prime the de-aerator until there is a steady flow
of oil into container [6]. Turn off the boiler then reconnect the
flexible oil inlet hose [7].
Turn on the boiler, set the programmer to ON and turn the room
thermostat up to create a demand for heat.
The oil level in the de-aerator will drop whilst the oil is being drawn
from the tank. If the de-aerator empties and the burner locks out
before the oil is drawn from the tank, you will have to prime the de-
aerator again.
NOTICE:
Salt based, softened water must not be used to fill
the central heating system.
The pH value of the system water must be between 6.5
and 8 or the appliance warranty will be invalidated.
NOTICE:
The concentration of inhibitor in the system should
be checked every 12 months or sooner if system
content is lost.
In cases where all attempts to find a micro leak have
failed, Worcester, Bosch Group supports the use of
Fernox F4 leak sealer.
ADEY 01242 546700 or www.adey.com
FERNOX 0330 100 7750 or www.fernox.com
SENTINEL 01928 704330 or www.sentinelprotects.com/uk
NOTICE:
Never run the appliance when the appliance/system
is unpressurised (sealed systems) or empty.
6720821683-11.1Wo
4
1
3
2
41


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Worcester-Bosch Greenstar Danesmoor Utility Regular - Utility System at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Worcester-Bosch Greenstar Danesmoor Utility Regular - Utility System in the language / languages: English as an attachment in your email.

The manual is 14.85 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info