Commissioning
Greenstar Danesmoor Utility 2022+ and Utility System 2022+ - 6 721 846 263 (2022/01) 43
Fig. 67 Burner head adjustment
6.4.5 Boiler lockout indicator on:
If the burner fails to establish a normal firing pattern or flame failure
occurs the flame monitoring photocell mounted in the burner body will
alert the burner control box to shut the burner down and provide a safe
lockout state indicated by the illumination of the lockout indicator (D).
Wait 2 minutes then press the lockout reset button D ( figure 70)
to initiate another start sequence.
Repeat procedure until a flame is established.
1. Start and run for 3 minutes then switch off.
Release the burner retainer nut (F).
Remove the burner.
Check for after-spurting from the nozzle, indicated by oil saturation
on the combustion head (item G, figure 70).
If after-spurting occurs:
Remove the combustion head (G) and electrodes, hold the burner
vertical to unscrew the nozzle and fill the nozzle holder with
kerosene.
Refit nozzle, electrodes, combustion head (G) and the burner.
Restart and run for 3 minute intervals until after-spurting stops.
Fig. 68
6.4.6 Combustion checks
Start and run for 20 minutes
Remove sampling point plug (K) to check the smoke reading is
between 0-1. If the smoke level is above 1, check the combustion
settings are correct and the oil nozzle is in good condition.
Fig. 69
▶Check the CO
2 levels and adjust the air shutter (L) setting according
to table 10.
Check the flue gas temperature is close to the values shown in the
table 10.
Turn off the electrical supply.
Isolate the oil supply to the burner.
Remove the oil pressure gauge.
Refit the blanking plug (A).
Check and rectify any oil leaks.
2. Switch on the oil supply.
Switch on the electrical supply.
Restart the boiler and run for 5 minutes.
Recheck the CO2 levels and if required, adjust the air shutter setting
(L) to obtain the correct CO2 level.
Refit the sample point cap (hand tighten only, do not over tighten)
and refit the burner cover.
D
X=0
1 mm
X
6720821683-23.1Wo
Smoke readings may be inaccurate until the smoke from
burning organic binder in the access door insulation has
ceased.
If the flue gas temperature is too high and the baffles are
correctly fitted, then reduce the oil pump pressure (B) 5-
10p.s.i. to compensate for nozzle variations.
1.
F
6720808218-59.1Wo
2.
K
6720808218-60.1Wo
43


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Worcester-Bosch Greenstar Danesmoor Utility Regular - Utility System at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Worcester-Bosch Greenstar Danesmoor Utility Regular - Utility System in the language / languages: English as an attachment in your email.

The manual is 14.85 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info