OPERATION INSTRUCTIONS
BEFORE USING YOUR APPLIANCE
Remove the exterior and interior packing
Before connecting the appliance to the power source, let it stand upright for approximately 4 hours. This will re-
duce the possibility of a malfunction in the cooling system from handling during transportation
SWITCHING ON/OFF THE AIR CONDITIONER
The appliance can be switched ON or OFF by pressing the POWER button on the control panel or the ON/OFF but-
ton on the remote control
COOLING MODE
In this mode, the air conditioner cools and dehumidifies the room. To activate this function mode, press the Mode
Control until the Cooling indicator light comes on. When the cooling mode is set, the compressor will start in ap-
proximately 3 minutes. In cooling mode, hot air is exhausted from the outdoor exhaust port and the exhaust hose
must be connected to exhaust out the hot air.
The temperature setting range of this air conditioner is from 61°F / 16°C to 89°F / 32°C. To set the temperature,
press the or buttons. This air conditioner has a 5°F temperature cushion which if the set temperature is within
5°F of the ambient temperature, the unit runs on fan only mode. This saves energy and prolongs the life of the com-
pressor of the air conditioner.
To set the fan speed, press the FAN button. In cooling mode, the difference in noise level between the 3 fan speeds
is not very noticeable when the compressor is on. Try setting the unit to Fan only mode, you should be able to hear
the difference between high and low fan speed settings.
A dual hose portable air conditioner will cool a room faster and will help minimize negative air pressure situation in
the room. If the outside temperature is much higher or more humid than the room, the intake hose can be covered
with the included cover and it will function like a single hose unit.
DEHUMIDIFYING ONLY MODE
In this mode, the air conditioner only dehumidifies the room, the compressor will activate intermittently depending on
the ambient temperature and the fan speed is set to LOW. To activate this function mode, press the Mode Control
until the Dehumidifying indicator light comes on. Please note that when switching function mode, there will be an
approximately 3 minute transition time. In dehumidifying mode, the exhaust hose is optional and the intake should
not be vented. If the exhaust is vented, warm air is exhausted to the outside and cooling may occur. If cooling is not
preferred, remove the exhaust hose and allow the warm air from the back to return to the room to avoid cooling. If
room temperature is higher than 77°F, the fan speed can be adjusted. If room temperature is lower than 77°F, the
fan speed is set at Low. The air conditioner does not have a humidistat in which a specific humidity level can be set.
FAN ONLY MODE
In this mode, only the fan of the air conditioner runs and circulates the air in the room. To activate this function mode,
press the MODE button until the Fan indicator light comes on. In this function mode, the temperature cannot be
set. Subsequently, set the desired fan speed by pressing the Fan button. Fan Only mode does not require the use of
exhaust and intake hoses.
HEAT MODE
In this mode, the air conditioner heats the room. To activate this function mode, press the Mode Control button until
the HEAT indicator comes on. When the heating mode is set, the compressor will start in approximately 3-5
minutes.
NOTE: In heating mode, cold air is exhausted from the outdoor exhaust port and the exhaust hose must be connect-
ed to exhaust out the cold air. If outside temperature is lower than inside temperature, air intake hose should be
blocked and unit will take in air from the air filter.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Whynter ARC-122DHP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Whynter ARC-122DHP in the language / languages: English as an attachment in your email.

The manual is 6,02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info