727497
16
Zoom out
Zoom in
Previous page
1/18
Next page
16
TROUBLESHOOTING
Problem Possible Causes Solutions
The portable air conditioner
does not turn on
Power failure / outage
The automatic switch, line fuse, or
breaker has been tripped
The power supply voltage is too low
The power cord is damaged
The L.C.D.I. power plug for the unit
is tripped
The internal water reservoir is full
Restore the power supply
Flip the switch / change the fuse / turn
the breaker back on. Also note that
you may have too many appliances
drawing power on one circuit, you may
need to move the other appliances to
another circuit
Move the unit onto another circuit with
the correct voltage
Call for service. Only authorized per-
sonnel should replace damaged pow-
er cord or power plug
Press the Reset button on the L.C.D.I.
power plug
Drain water from the air conditioner
Possible loose internal connection.
Please contact Whynter for service
The unit turns on but the com-
pressor does not turn on (the
fan runs but the unit is not
cooling)
The room temperature is outside of
the operational tolerances of the
unit
The Cooling mode is not on
The compressor has not turned on
yet because of its time delay
The set temperature is too high
The internal water reservoir is full
and Warning Light appears on dis-
play
This unit is designed to work in ambi-
ent temperatures of 64°F to 90°F
Press Mode Control until the Cooling
indicator light is shown on the display
Give the compressor 3 minutes to turn
on after the Cooling mode has been
selected
Set the air conditioner to a lower tem-
perature. It is recommended to set the
temperature to at least 5°F of the am-
bient temperature
Either manually drain the water by
removing the drain plug or allow the
unit to exhaust the water itself by run-
ning the fan only mode. Then cooling
will resume
Possible loose internal connection.
Please contact Whynter for service
The air coming out of the unit
is not very cold, or the airflow
volume is weak
The filters are dirty or obstructed
The air intake or exhaust is ob-
structed
The unit is set in DEHUMIDIFY or
FAN mode
The unit is set to low fan speed
Clean the air filters
Make sure there is at least 20" of
clearance from the air intake. Make
the length of the exhaust hose is as
short as possible
Set the unit to Cooling mode
Set the unit to a higher fan speed
Many common portable air conditioner problems are easily resolved. Try the troubleshooting suggestions
below to see if the problems can be resolved before having to contact the service department.
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Whynter ARC-122DHP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Whynter ARC-122DHP in the language / languages: English as an attachment in your email.

The manual is 6,02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info