Important:
The soldering tool becomes hot during the calibration
process. Never leave combustible materials near the hot
soldering tool
Calibration of the control unit (without soldering iron) can also
be carried out by a calibration laboratory. Here, the calibrati-
on values for the soldering iron are simulated.
5.2.2 Change Calibration
DOWN button pressed
Calibration at 100 °C/212°F.
The station adjusts the temperature of the soldering iron to
100°C. Once the temperature becomes static (at which point
the indicator flashes), the soldering tip temperature (external
measuring device) is compared to that shown on the display.
If a temperature deviation is found, the UP/DOWN buttons
can be used to make adjustments. A maximum temperature
adjustment of ±40°C/±72°F is possible. If the measured tem-
perature matches that shown on the display, press the I-II-
III button (CAL) to confirm.The temperature deviation is reset
to 0. This concludes the calibration at 100°C/212°F.
Press the 2 button (EXIT) to exit the menu without saving
any changes.
UP button pressed
Calibration at 450°C/842°F.
The station adjusts the temperature to 450°C/842°F. Once
the temperature becomes static (at which point the indicator
flashes), the soldering tip temperature (external measuring
device) is compared to the actual value shown on the display.
If a temperature deviation is found, the UP/DOWN buttons
can be used to make adjustments. A maximum temperature
adjustment of ±40°C/±72°F is possible. If the measured tem-
perature matches that shown on the display, press the
I-II-III button (CAL) to confirm. The temperature deviation is
reset to 0.
This concludes the calibration at 450°C/842°F.
Press the 2 button (EXIT) to exit the menu without saving
any changes.
When both calibration points 100°C (212°F) / 450°C
(842°F) have been balanced, the calibration process is com-
plete.
Press EXIT to exit the menu 2.
5.2.3 Station code (ID number)
When using multiple WD stations, you can assign a number
to each soldering station for identification purposes. If the
optional USB interface is used, several WD stations, with the
full range of functions,can be remote-controlled. For this pur-
pose, each WD station requires a station code for unambigu-
ous identification (ID number).
Use the UP/DOWN buttons to change the ID number.
Switch to the previous menu item with I.
Switch to the next menu item with II.
Button III is used to exit the menu again.
English
41
CAL EXIT
450°C/842°F
100°C/212°F
Temperature
deviation
Temperature
deviation
CAL EXIT
48


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Weller WD 2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Weller WD 2 in the language / languages: All languages as an attachment in your email.

The manual is 6,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info