3.5 WELDING MILD STEEL
3.5.1 MIG WELDING WITH GAS PROTECTION
Either 85% Argon + 15% CO² or 100% CO² may be
used for welding mild steel.
- Connect the grounding cable to the Negative
output terminal (2) and connect the terminal of
the grounding cable to the workpiece. Connect
the terminal of the earth lead, inside the reel
compartment, to the negative pole.
- Mount the MIG torch supplied with the welding
machine on the fitting (1). Connect the power cable
leaving the torch, inside the reel compartment, to
the positive pole.
- Select the welding current by means of the setting
knob (16).
- Move the torch near the welding point and press
the trigger. Adjust the potentiometer knob until the
welding is done with a constant, continuous noise.
Or see the table below for some settings.
- If the speed is too fast, the wire tends to stick to the
piece and cause the torch to skip; if the speed is too
low, the wire melts in spaced drops or the arc does
not remain lit.
- When you have finished welding, turn off the
machine (3) and close the gas cylinder.
WK MIG 2125
Guidelines for settings
Thickness in mm Meters per minute Voltage
Steel SG-2 0,6mm
1,0mm 7,7m/min 14,5V
1,5mm 10,0m/min 17,5V
2,0mm 12,7m/min 18,9V
2,5mm 13,0m/min 21,0V
Steel SG-2 0,8mm
1,0mm 2,8m/min 14,5V
1,5mm 6,0m/min 17,0V
2,0mm 7,3m/min 18,0V
2,5mm 8,6m/min 18,8V
3,0mm 10.0m/min 19,5V
3,5mm 11,5m/min 22,0V
Steel SG-2 1,0mm
1,5mm 3,3m/min 16,2V
2,0mm 4,5m/min 16,4V
2,5mm 5,3m/min 18,0V
3,0mm 6,0m/min 18,5V
3,5mm 6,6m/min 19,2V
CuSi3 0,8mm
0,8mm 4,2m/min 13,3V
1,0mm 5,0m/min 13,4V
1,5mm 10,0m/min 14,8V
3.5.2 MIG WELDING WITHOUT
GAS PROTECTION
The actions to prepare the machine for welding are the
same as those described previously, but for this type of
welding proceed as follows:
- Mount a coil of flux-cored wire for welding without
gas.
- Mount the MIG torch supplied with the welding
machine on the fitting (1). Connect the power cable
leaving the torch, inside the reel compartment, to
the negative pole.
- Connect the grounding cable to the Negative output
terminal (2). Connect the terminal of the earth lead,
inside the reel compartment, to the positive pole.
- Select a program suited for flux-cored wire.
- Use only diam. 0.9 flux cored wire that complies
with the standard AWS AS.20 E71, suitable for use
without gaseous protection.
- Connect the terminal of the grounding cable to the
workpiece.
NOTE: For compact, well-protected welds always work
from left to right. (figure 4).
3.5.3 MIG WELDING ALUMINIUM
The welding machine must be prepared as for welding
mild steel with gas protection, but with the following
differences:
- 100% Argon as the protection gas for welding.
- A welding wire with a composition suitable for the
base material to be welded. Use wire feeder rollers
suitable for aluminum wire.
- Use wire feeder rollers specifically designed for
aluminium, and never use them on other materials.
REMEMBER that cleanliness is quality!
- The wire reels must be stored in plastic bags with
dehumidifying packets.
- For the correct welding angle see figure 4.
3.5.4 MIG WELDING STAINLESS STEEL
The welding machine must be prepared as for welding
mild steel with gas protection, but with the following
differences:
- Cylinder containing 98% ARGON + 2% 02
(recommended composition)
- Reel of stainless steel wire compatible with the
composition of the material to be welded.
- The recommended torch angle are shown in figure 4.
Figure 4
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Weldkar MIG 2125 INVERTER WELDER at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Weldkar MIG 2125 INVERTER WELDER in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 3,4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info