802209
18
Zoom out
Zoom in
Previous page
1/379
Next page
EN
6 5110757E OI II Webasto Pure
NOTE
In some countries, single-phase charging is limited to
a defined current. The local connection requirements
must be observed.
All protective devices specified below must be designed
such that the charging station is disconnected from the
grid in the case of a fault. You must meet national install-
ation regulations and standards when selecting the pro-
tective device.
8.2.1 Dimensioning of the Residual Current
Circuit Breaker (RCCB)
The national installation regulations generally apply. Un-
less otherwise specified therein, each charging station
must be protected by an appropriate residual current
device (RCD type A) with a trip current of ≤30mA.
8.2.2 Dimensioning of the circuit breaker
The circuit breaker must conform to IEC 60898. The let-
through energy (I²t) must not exceed a maximum 80,000
A²s.
Alternatively, a residual current circuit breaker combina-
tion (RCBO) according to EN 61009-1 can be used. The
aforementioned parameters apply for this circuit breaker
combination.
8.2.3 Mains isolation device
The charging station does not have its own main ON/OFF
switch. The protective devices installed in the power sup-
ply system are therefore also used to disconnect the
power supply.
8.3 Installation
See also chapter15, "Assembly" on page 9. The sup-
plied installation material is intended for mounting the
charging station on a concrete wall or on an external
stand. For installation on a stand, the mounting material
is included in the scope of delivery of the stand.
üScope of delivery is checked for completeness.
uTake into account the mounting position at the install-
ation location. See Fig. 14.
NOTE
The central hole must be drilled!
uRemove the drill template at the perforation from the
packaging.
uMark the four positions of the drill holes at the install-
ation location using the drill template. See Fig. 14.
uDrill 4 holes of Ø 8mm in the marked positions.
uPosition the bracket over the upper holes and mount
using 2 wall plugs and 2 screws, 6x70mm, T25.
uRemove the lower cover from the connection area of
the charging station.
Fig.8
uRemove the spiral antikink protection from the con-
nection area of the charging station and place it with
the other supplied material.
uFor surface mounting, make a recess for routing the
lead on the back of the charging station using the des-
ignated lateral predeterminedbreakingpoints (if ne-
cessary deburr the edge of the break using a round
file).
uInsert the lead through the designated lead-through
and fit the charging station on the previously mounted
bracket.
uMount the charging station using 2 screws,
6x90mm, T25 using the mounting holes in the lower
connection area. Do not exceed the max. torque of
6Nm.
8.3.1 Connecting the charging cable
uPush the spiral antikink protection with the threadless
opening forward over the supplied charging cable.
uGuide the charging cables through the previously pre-
assembled sealing clip.
NOTE
Ensure correct fit of the previously pre-assembled rub-
ber seals in the sealing clip.
uPush the charging cable at least 10mm beyond the
upper edge of the clamping area of the strain relief
clamp.
uTurn the antikink protection spiral several turns onto
the sealing clip.
NOTE
Do not tighten yet.
Fig.9
uScrew in the supplied strain relief clamp in the correct
position on the charging cable.
NOTE
The strain relief clamp has two position options for
charging cable versions 11kW and 22kW.
Ensure that the “11 kW installed” label for an 11 kW
charging cable is visible.
uFit the strain relief clamp in the correct mounting posi-
tion using the supplied self-tapping Torx screws
(6.5x25mm) and tighten to 5.5Nm. (Attention: Do
not overtighten screws).
uThe strain relief clamp must be flush when securely
screwed in.
NOTE
Perform a tension test on the charging cable to make
sure that the cable cannot move.
uScrew the antikink protection spiral onto the sealing
clip with a torque of 4Nm.
uUsing the slot-head screwdriver (3.5 mm), connect the
individual cable ends according to the specification in
the illustration on the right terminal block with the
"out" label.
uTo do this, insert the screwdriver in the designated up-
per opening of the spring relief for the terminal block
and open the clamping spring.
uNow insert the individual wire into the designated
connection opening of the terminal block (lower open-
ing).
Charging cable Description
Blue N
Brown L1
Black L2
Grey L3
Yellow-green PE
Black-white Control cable (CP)
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Webasto Pure II at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Webasto Pure II in the language / languages: All languages as an attachment in your email.

The manual is 28.17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info