7
Zone 1 relay selection:
You can choose the function of the
zone 1 relay (output).
As a normal zone like the others.
Or to control the cooling system of
the installation.
01: Standard uses.
The output 1 is used to manage a
standard zone.
H:C: Cooling information:
The output 1 is used to manage the
cooling system.
In the operating mode menu:
With (+) & (-) you can choose the
functioning mode (Heat or Cool )
Cooling function .
If you have a cold request on any zone
the Output 1 LED will shine in green and
the Output 1 will switch on.
If you select the heating function the
zone1 is stay inactive.
Type of degrees displayed
°C: Celsius degrees.
°F: Fahrenheit degrees.
Type of time displayed
Default: 24H00
Adjustable: 12:00 am/pm
Proportional band cycle:
Selection of the proportional band (PWM)
duration in minutes
You could decrease this time up to 8min only
if your installation as fast thermal reacting
behavior
(Liquid concrete floor, ...)
Default: 15 minutes
Adjustable: 15 or 08 min
Proportional band value:
Value of the proportional band (PWM)
Adjust this value like this:
A well insulated house « 1.2°C »
A not insulated house « 2°C »
Default: 2.0°C
Adjustable: 2.0°C or 1.2°C
Pump exercise:
Select PUMP to perform a 2 minute pump
exercise each 12h00 only if the PUMP relay
has not been activated since 24 Hours.
no: function deactivated.
PumP: Function activated
ITCS: Intelligent Temperature Control
System
Select ItCS to activate the Intelligent
Temperature Control System. The Timer RF
will learn and start in advance the heating of
the zones to assure that the desired
temperature is already reached when
following the program.
NO: function deactivated.
ItCS: Function activated
Press (OK) during 5 seconds to reset the installation.
All parameters are replaced by default value.
Standard thermostat Radio configuration mode (see the corresponding section)
Press (OK) on this parameter to exit the parameters menu end come back to the
main display.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Watts WFHC-MASTER H and C-RF 6 ZONES at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Watts WFHC-MASTER H and C-RF 6 ZONES in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 2.17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info