GB
around (about 80 cm). Pay also attention to joisted
oor layers and any electric wiring.
5. Keep a distance of at least 50 cm (in all directions)
between the stove and supporting steel construc-
tion parts.
6. Shield o all combustible materials within a radius
of 80 cm from the stove openings with non-com-
bustible materials.
7. Never cover the chimney breast with combustible
material (e.g. paper covering).
8. The wall behind the stove must consist of, or be
insulated with, re-proof materials. The insulation
material must resist a temperature of 700 °C and
have a density of 80 kg/m3. Please see for insulation
materials table page 24).
9. Avoid heat transmission when placing the stove.
Heat transmission of a burning stove can penetrate
the wall and even cause re damage on the other
side of the wall. Prevention is better than cure.
Installation
The Square is tested in accordance with the international
EN 13229 standardization, and has an extra additional
standardization for optimally environment-friendly
heating devices related to ue gases (Section 15a B-Vg.
Des BmfWA). The stove can be connected to a ue tube
to which several stoves are connected. The ue tube has
a diameter of 150 mm.
Supply of combustion air
The stove must have enough supply of fresh combustion
air. If necessary, make an extra air supply opening as
close to the stove as possible to avoid draught. An extra
opening for air supply is always required if:
the space has a heat recovery system.
the space has a central exhaust system.
there is a cooker hood in the same space.
The air supply opening must be closable if it goes through
a re-resistant wall. When there are several combustion
devices in the same space there must be enough air
openings to guarantee proper combustion.
Fans (optional)
The fans can’t be placed after the stove has been
installed. When fans were ordered they will be installed
in the factory.
Always connect the fans to an earthed wall socket.
Moreover there must be the possibility to disconnect
the stove from the electricity supply any service or
maintenance.
When starting the fans, they will start with their fastest
speed, you can regulate the speed of the fans with the
knob on the left side. Please be aware that the fans will
produce noise. All eorts are made to reduce this noise
as much as possible.
When refuelling the stove it’s advised to turn the fans
o preventing the smoke from being drawn out of the
stove.
The technical specications from the fans and the control
unit are as follows:
Control unit:
Voltage 230V / 50Hz
Size (L x W x H) 75 x 26 x 20 mm
Fan:
230V ~ 50Hz 120 mA 20W
Connecting the stove
The Square is a heavy insert. Check whether the oor on
which the stove is placed can carry this weight without
problem. You must follow the directions given in de
previous chapter on ‘Preparation before installing.
Please mind your back and the oor during installation!
Mounting the Square:
1. Check the packing. If you detect any visible dam-
age, please notify the supplier.
2. Take the stove from the box.
3. Remove the ue collar from the stove by unscrew-
ing the 4 bolts.
4. Place the insert at its nal position. Make sure that
it is positioned right beneath the chimney. If the
fans are installed please make sure the wire does
not crack or break during installation.
5. Connect the ue collar to the ue system with the
upper sections tting into the lower sections.
6. Place the bae plate into the stove.
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wanders 75 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wanders 75 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 4,67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info