20
Installation Instructions for the Square
General instructions 20
Preparation 20
Installation 21
Connecting the stove 21
Repairs 22
General instructions
The Square is tested in accordance with the international
EN 13229 standardization, and has an extra additional
standardization for optimally environment-friendly
heating devices related to ue gases (Section 15a B-Vg.
Des BmfWA). The stove can be connected to a ue tube
to which several stoves are connected. The ue pipe has
a diameter of 150 millimetres.
The heating device must be placed by an acknowledged
installer and according to the installation instructions
given below. The national and local rules and regulations
for placing and using wood-burning stoves are equally
applicable. WANDERS does not give any guarantee if
the Square is connected or installed incompletely or
incorrectly.
It is not allowed to place the stove in:
Arcades and corridors accessible to the public.
Stairwells, except in buildings with no more than 2
dwellings.
Spaces where highly ammable or explosive materials
are used.
Spaces where an exhaust system is used or where a
mechanical exhaust system is placed, except when
the air supply is taken directly from outside to assure
a hazardless combustion.
Preparation
The chimney ue
Before placing the stove you must observe the following
points:
If the stove is connected to an existing chimney, you
must rst have the chimney professionally cleaned
and checked by a qualied chimney sweep company.
Any cut-o valves or stop valves must be removed.
The ue tube of the stove must be connected with the
chimney without diversions.
The underpressure in the chimney must be at least 12
Pa or 0.12 mbar.
The chimney ue must always end up in outlet area 1
(see the drawing and the table below)
At the time of placing the stove, the chimney ue
must be clean, leak-proof and without obstructions,
and must have a diameter of 150 mm.
Any bends in the ue tube must not exceed 45
degrees.
Ensure that the chimney tube can discharge the ue
gases adequately, properly and safely.
Fire Safety
For reasons of re safety is it important to observe the
instructions below before installing the stove.
1. If the oor around the stove is made of combustible
material, you must use a oor slab.
The oor slab must measure at least:
- 50 cm from the stove on the front side of the door
- 30 cm from the stove on the sides of the door.
2. Keep at least a distance of 80 cm between the stove
and combustible objects such as curtains, wooden
objects (cupboards and paintings) and glass objects.
Keep the same distance from the ue tube.
3. Wooden construction parts within the radiation
range of the stove (80 cm from the exterior of the
stove) must be covered with reproof material.
4. If the ue tube goes through a ceiling and/or roof
that consist of ammable materials, the ceiling and
the roof must be covered with reproof materials all
1
3 3
A X
X > 23˚
3
X
X < 23˚
1
500 mm
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wanders 75 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wanders 75 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 4,67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info