694505
23
Zoom out
Zoom in
Previous page
1/64
Next page
23
GB
Technical details Square
Door latch Ba I/II Ba I/II Ba I/II
Nominal capacity* 6 kW 7 kW 8 kW
Flue pipe 150 mm 150 mm 150 mm
Maximum lling in the stove 3 kg 3 kg 3 kg
Volume of the combustion chamber 0,03 m
3
0.052 m
3
0,088 m3
Surface bottom of the combustion chamber 0,11 m
2
0,19 m
2
0,22 m2
* Nominal heat is obtained with a chimney draft of 0,12 mBar
Fuel, wood logs (30 x 10 cm)
Maximum supply 3 pieces
Primary air valve max
Secundary air outlet max
Fuel burning period about 1 hour
Flue gas values in accordance with DIN 4705, DIN 18895 part 2
Square 60 Square 68 Square 75
When door is closed Wood Wood Wood
Flue gas quantity 6 7,2 6,8 g/s
Flue gas temperature 335 335 365
o
C
Pre-pressure 0,12 0,12 0,12 mBar
Eciency 78,4 79,0 78,1 %
CO at 13% O
2
0,10 0,09 0,09 %
Particulate matter 28 26 30 mg/m
3
Certicate Institute
1625
Test standard EN13240 Test report nr. RRF - 29 09 1895 (Square 60)
Test report nr. RRF - 29 09 2028 (Square 68)
Test report nr. RRF - 29 09 2182 (Square 75)
Target value for the volume of the space to be heated:
Not all spaces meet the present insulating values. According to DIN 18893, the following values can be taken for
the volume of the space to be heated:
If heating circumstances are favourable
In less favourable circumstances:
In unfavourable circumstances:
Calculate according to DIN 4701
90 - 105 - 120 m
3
(60 - 68 - 75)
70 - 85 - 100 m
3
(60 - 68 - 75)
For temporary heating you may assume a reduction of 25% for the volume to be heated if the interval is more than
8 hours.
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wanders 75 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wanders 75 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 4,67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info