649001
9
Zoom out
Zoom in
Previous page
1/30
Next page
Super Finish 27 • 31
31
GB
Starting operation
Pay attention to the fact that the red inlet (2) is inserted into
the coating material inlet.
Screw the upper hopper (3) onto the coating material inlet 3.
(4).
Hang the return pipe (5) into the upper hopper.4.
Screw the union nut (6) on the return pipe (5) onto the
5.
connection (7).
3
5
4
3
2
5
6
7
4
1
 
Screw the high-pressure hose (g. 8, item 1) onto the hose 1.
connection (2).
Screw the spray gun (3) with selected tip onto the high-
2.
pressure hose.
Tighten the union nut on high-pressure hose so that no
3.
coating material escapes.
3
5
4
3
1
2
4.4 
Attention
The connection must take place through a
correctly earthed two-pole and-earth socket
outlet.
Before connection to the mains, pay attention to the fact
that the mains voltage agrees with the information on
the makers’ name plate on the rear of the unit.
The green control lamp will light up as soon as the mains plug
has been connected.
4.5 

 

Submerge suction pipe into a vessel lled with a suitable
cleaning agent
 
2.
Fill suitable cleaning agent into the upper hopper.
Set multifunction switch (g. 9, item 1) to
3.
(ON–
circulation); the unit commences to run. Turn pressure
regulation knob (2) to the right until stop.
Wait until the cleaning agent ows out at the re-turn pipe.4.
Set multifunction switch (1) to
5.
(spray). Pull trigger guard
of spray gun.
Spray cleaning agent from the unit into an open collection 6.
container.
3
5
4
2
1
 

Turn pressure regulating knob (g. 10, item 1)
1.
three
revolutions to the left.
Set multifunction switch (2) to
2.
(ON circulation). The
hydraulic system is ventilated. Leave the unit on for two to
three minutes.
Then turn the pressure regulating knob (1) to the
3.
right until
stop. Sound of the inlet valve is audible.
If not, repeat points 1 and 3. 4.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wagner Super Finish 27 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wagner Super Finish 27 in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 5,64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info