i) Temperature measurement
Do not get the temperature probe wet!
1. Set the function dial to °C°F.
2. Short press the SEL button to select a unit of measurement, “°C” or
°F” will show on the display.
3. Connect the K-type thermocouple to the terminals.
- TEMP +” plug to the terminal.
- COM -” plug to the COM terminal.
4. Measure the temperature at the probe tip.
- “OL” will appear on the display when the DMM is turned on.
- The measured temperature should be < 400 °C / 752 °F (°F = °C × 1.8 + 32)
5. Whennishedmeasuring,disconnectthetestleadsandswitchthepowerOFF.
j) Current measurement / Frequency (40 to 400 Hz)
This measuring function is suitable for measuring mains current.
Topreventpossibleelectricshock,reorpersonalinjury,switchoffthepowersupplyofthecircuit,andthen
connect the DMM to the circuit in series before measuring the current.
If the range of the measured current is unknown, always start at the highest measurement range and switch
down to lower ranges if needed.
There are fuses inside “10 A” and “mA μA” input terminals. Do not connect the test leads to circuits in
parallel.
A warning will sound when measured values are out of range >10 A.
Measuring >5 A must only be performed for max. 30 seconds and at 15 minute intervals.
1. Set the function dial to µA , mA , or A , the corresponding unit of measurement will appear on the display.
2. Short press the SEL button to cycle through “DC”, “AC”, “Hz”.
3. Connect the test leads to the terminals:
- Red test lead to the terminal.
- Black test lead to the COM or 10A max terminal
4. Connect the test lead probes to the circuit in series.
5. Read the value on the display.
- DC current: The polarity is shown together with the measured value.
- AC current: Values are given in true RMS.
- Frequency:Measuringrangeis40to400Hz(inputamplitude≥range×50%).
6. Whennishedmeasuring,disconnectthetestleads,powerthecircuitdownandswitchtheDMMpowerOFF
600 mA max
FUS ED
600 V max
10A m ax
FUS ED
600 V max
MAX 3 0sec EA CH 15m in
-
+
46


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Voltcraft VC190 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Voltcraft VC190 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 15,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info