g) Capacity measurement
Make sure all circuit parts, circuits, components, and other objects of measurement are disconnected from
the voltage supply and fully discharged.
Always observe polarity with electrolyte capacitors.
1. Set the function dial to .
2. Short press the SEL button 1x to select capacity measurement, “nF” unit or capacitance will show on the display.
3. Connect the test leads to the terminals:
- Red test lead to the terminal.
- Black test lead to the COM terminal.
4. Connect the test lead probes to the correct test points on the capacitor.
- Always observe the polarity with electrolyte capacitors.
- “OL” will appear on the display if the polarity is reversed or if the circuit is shorted.
- Wait until the displayed value has stabilized. This may take a few seconds for capacities >40 µF.
5. Whennishedmeasuring,disconnectthetestleadsandswitchthepowerOFF.
h) Frequency (>10 Hz) / duty ratio measurement (%)
This measuring function is not suitable for measuring mains current!
The DMM can be used to measure and indicate signal voltage frequencies up to 1 MHz.
The maximum input amplitude is 30 Vrms.
Please observe the input values in the technical data.
1. Set the function dial to Hz%, Hz will appear on the display.
2. Short press the SEL button to switch between frequency “Hz” and duty ratio “%” measurement.
Frequency measurements: Short press RANGE to toggle through ranges (indicated by decimal position).
3. Connect the test leads to the terminals:
- Red test lead to the terminal.
- Black test lead to the COM terminal.
4. Connect the test lead probes to the correct test points in the circuit.
Duty ratio: The pulse duration of the positive half wave is displayed as a percentage. 50% is displayed for
a symmetrical signal.
5. Whennishedmeasuring,disconnectthetestleadsandswitchthepowerOFF.
45


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Voltcraft VC190 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Voltcraft VC190 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 15,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info