Proceed as follows to perform a continuity test:
- Switch the receiver unit on by pressing the switch “ON/OFF” (13).
The switch snaps into place and the LED display (1) shows “00”. The
operating indicator “OP” will light up.
- Press the button “R test” (2). The display “OP” will go out. The conti-
nuity test function is active.
- Connect the two banana clips with the lines to be tested. In case of
low-impedance continuity (approx. <100 Ohm), an acoustic signal
sounds.
- Terminate the continuity test by pressing the button “R test” and turn the receiver unit off manually
(button “ON/OFF”).
c) DC polarity test
The receiver unit can determine the polarity of low voltages of 5 to 16 V/DC.
Proceed as follows to perform the continuity test:
- Switch the receiver unit on by pressing the switch “ON/OFF” (13).
The switch snaps into place and the LED display (1) shows “00”. The
operating indicator “OP” will light up. If “OP” is not lit, please press the
button “R test” (2) to release it.
- Press the button “V check” (3). The display “00” will go out. The polar-
ity test function is now active.
- Connect the red banana clip with the positive pole and the black banana clip with the negative pole
of the voltage source. The LED indicator now shows “UU”.
- If there is no display, the polarity may be reversed or the voltage is outside of the test range (5 – 16
V/DC). Perform a counter-polarity test to limit the two possibilities down to one.
- Release all press switches and turn the receiver unit off manually (button “ON/OFF”).
d) Cable allocation
Up to 16 conductors can be indentified with the cable allocation function. All you need for this is a known
reference line/cable/pipe, e.g. a domestic water or heating pipe.
The transmitter (REMOTE UNIT) codes each test line with a number. These numbers are indicated on
the corresponding banana clips.
The receiver (DMM) decodes the signal and indicates the current line number on the LED display.
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Voltcraft LZG-1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Voltcraft LZG-1 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 3,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info