Auto power OFF function
The DMM turns off automatically after 15 minutes if no button or switch is operated. This function saves
battery power and extends the service life.
To reactivate the DMM after automatic shutdown, use the rotary switch or press any function key
(MODE, MAX, HOLD).
2. MEASURING MODE LINE ALLOCATION
In no event exceed the max. permitted input value of 16 V/DC. Do not contact circuits
or parts of circuits if there could be voltages higher than 25 V ACrms or 35 V DC pre-
sent within them. Mortal danger!
Before measuring, check the permanently connected measuring lines for damage
such as, for example, cuts, cracks or squeezing. Defective measuring cables must
no longer be used. Risk of wrong measuring results!
Measuring is only permitted with closed housing and battery compartment.
Always turn both devices for cable allocation off after operation. The devices do not
turn off automatically like the DMM.
The cable allocator consists of two parts. The transmitter (REMOTE UNIT) is required for operation; it
applies the corresponding numerical coding to the test lines. The receiver in the DMM decodes this ID
and shows the corresponding number on the LED display (1). All you need for identification is a known
reference line. This may also be an available water pipe, heating pipe, etc.
a) Turning the cable allocators on (transmitter + receiver)
The remote unit (transmitter) and the receiver (in the DMM) is activated and deactivated via a press
switch (13 and 16). When the switch is pressed, both devices are turned on. To turn off press the switch
again.
Operation is signalled with the display “OP”. The display “OP” (1) is lit on the DMM receiver unit; the dis-
play “OP” (17) blinks on the transmitter unit.
Prior to working with the cable allocation device, you have to insert the enclosed bat-
teries. Inserting and changing the battery is described in the chapter “Maintenance
and cleaning”.
b) Continuity test
Continuity tests can be performed with the receiver unit on the DMM. Resistances of approx. <100 Ohm
are signalled acoustically.
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Voltcraft LZG-1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Voltcraft LZG-1 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 3,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info