4.5.4 Configuring alarms and troubles
The following table provides you with a detailed description of each option and its configuration settings. To select an
option and change its configuration, refer to section 4.5.1.
Option
Configuration Instructions
31:PANIC ALARM
Define whether or not the user will be allowed to initiate a Panic Alarm from keypads (by
simultaneously pressing the two Panic buttons) or keyfobs (by simultaneously pressing the
Away and Home buttons), and whether the alarm will be silent (that is, only reporting of the
event) or audible (that is, the sirens will also sound).
Options: audible (default); silent and disabled.
32:DURESS ALARM
(not applicable in UK)
A duress (ambush) alarm message can be sent to the Monitoring Station if the user is forced to
disarm the system under violence or menace. To initiate a duress message, the user must
disarm the system using a duress code (2580 by default).
To change the code, enter the new 4-digit of the new Duress code at the position of the
blinking cursor or enter 0000 to disable the duress function and press .
Notes: The system does not allow programming a duress code identical to an existing user
code.
33:INACTIVE ALRT
Previously known as
NOT ACTIVE
If no sensor detects movement in interior zones at least once within the defined time window,
an inactive alert event is initiated.
Define the time window for monitoring the lack of motion.
Options: disabled (default); after: 3/6/12/24/48/72 hours
34:TAMPER ALARM
Define whether the Tamper switch protection of all zones and other peripheral devices (except
the control panel) are active (default) or not active.
Warning!: If you select
not active
, be aware that no alarm or report will be initiated in case of
tampering with any of the system peripheral devices.
35:AC FAIL REPRT
To avoid nuisance reporting in case of short interruptions in the house of AC power, the
system reports an AC Fail message only if the AC power does not resume within a pre-
determined time delay.
Options: after 5 minute (default), after 30 minute, after 60 minute or after 3 hours.
Note: To comply with EN requirements, the time delay must not exceed 60 min.
36:CONFIRM ALARM
Previously known as
CONFIRM TIME
If two successive alarm events occur within a specific time window, the system can be
configured to report the second alarm event as a confirmed alarm (see section 4.6.3 option
61). You can activate this feature and set the respective time window.
Options: disable (default in USA); in 30/45/60 (default)/90 minutes
Note: In some PowerMaster-360 variants, this menu is displayed in the Operation Mode only
(see section 4.14).
37:ABORT TIME
The PowerMaster-360 can be configured to provide a delay before reporting an alarm to the
Monitoring Station (not applicable to alarms from 24H SILENT and EMERGENCY zones).
During this delay period, the siren sounds but the alarm is not reported. If the user disarms the
system within the delay time, the alarm is aborted. You can activate the feature and select the
Abort Time interval.
Options: in 00 (default in USA)/15/30 (default)/45/60 seconds; in 2/3/4 minutes
Note: In some PowerMaster-360 variants, this menu is displayed in the Operation Mode only
(see section 4.14).
38:CANCEL ALARM
Previously known as
ALARM CANCEL
The PowerMaster-360 can be configured to provide a Cancel Alarm time window that starts
upon reporting an alarm to the Monitoring Station. If the user disarms the system within that
cancel alarm time, a cancel alarm message is sent to the Monitoring Station indicating that
the alarm was canceled by the user.
Options: not active (default in USA); in 1/5 (default)/15/60 minute(s) and in 4 hours.
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Visonic Powermaster-360 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Visonic Powermaster-360 in the language / languages: English as an attachment in your email.

The manual is 2.8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info