4.5.2 Configuring arming/disarming and exit/entry procedures
The following table provides you with a detailed description of each option and its configuration settings. To select an
option and change its configuration – refer to section 4.5.1.
Option
Configuration Instructions
01:ENTRY DELAY1
02:ENTRY DELAY2
Two different entry delays allow the user to enter the protected site (while the system is in the
armed state) via dedicated exit/entry doors and routes without causing an alarm.
Following entry, the user must disarm the control panel before the entry delay expires. Slow-
rate warning beeps start sounding via the Configuration device (PC or mobile) once the door is
opened, until the last 10 seconds of the delay, during which the beeping rate increases. The
ENTRY DELAY 1 and ENTRY DELAY 2 options allow you to program the time length of these
delays.
Options: 00 seconds; 15 seconds (default for entry delay 2); 30 seconds (default for entry
delay 1); 45 seconds; 60 seconds; 3 minutes and 4 minutes.
Notes:
1. In some PowerMaster-360 variants, these menus are displayed in the Operation
Mode only (see section 4.14).
2. To comply with EN requirements, the entry delay must not exceed 45 sec.
03:EXIT DELAY
This option allows programming the time length of the exit delay. An exit delay allows the user
to arm the system and leave the protected site via specific routes and exit/entry doors without
causing an alarm. Slow-rate warning beeps start sounding via the Configuration device (PC or
mobile) once the arming command has been given, until the last 10 seconds of the delay,
during which the beeping rate increases.
Options: 30 seconds; 60 seconds (default); 90 seconds; 120 seconds, 3 minutes and
4 minutes.
04:EXIT MODE
The Exit Delay time can be further adjusted according to your preferred exit route. The control
panel provides you with the following Exit Mode options:
A: normal - The exit delay is exactly as defined.
B: restrt+arm home - Exit delay restarts when the door is reopened during exit delay. If no
door was opened during exit delay AWAY, the control panel will be armed HOME.
C: restart>reentry - The exit delay restarts when the door is reopened during exit delay. The
restart occurs once only. Restarting the exit delay is helpful if the user re-enters
immediately after going out to retrieve an item that he left behind.
D: end by exit - The exit delay expires (ends) automatically when the exit door is closed even if
the defined exit delay time was not completed.
Options: normal (default); restrt+arm home; restart>reentry and end by exit.
Note: In some PowerMaster-360 variants, this menu is displayed in the Operation Mode only
(see section 4.14).
05:QUICK ARM
Define whether or not the user will be allowed to perform quick arming or not. Once quick
arming is permitted, the control panel does not request a user code before it arms the system.
Options: OFF (default) and ON (default in USA).
06:BYPASS ARM
Define whether or not the user will be allowed to manually bypass individual zones, or allow
the system to perform automatic bypassing of open zones during the exit delay (i.e. force arm).
If a zone is open and forced arming is not permitted, the system cannot be armed and NOT
READY is displayed. If no bypass is selected, neither manual bypassing nor force arming is
allowed which means that all zones must be secured before arming.
Options: no bypass (default); force arm and manual bypass (default in USA).
Notes:
1. To comply with EN requirements, "manual bypass" must be selected.
2. The option force arm is not applicable in the UK.
3. A zone in Soak Test mode that is configured as bypass will trigger a test fail event if
the system detects a potential alarm event.
4. There is no limit of reported events when a bypass zone is in Soak Test mode.
07:LATCHKEY ARM
When ON, a latchkey message will be reported by SMS message to users (see Note) upon
disarming by a latchkey user (users 5-8 or keyfob transmitters 5-8). This mode is useful when
parents at work want to be informed of a child’s return from school.
Options: OFF (default) and ON.
Note: To enable the reporting, you must configure the system to report alrt events to Private
users (Latchkey belongs to the alerts group of events). Refer to section 4.6.4 REPORTED
EVENTS option in both
VOICE REPORT
&
SMS REPORT
menus.
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Visonic Powermaster-360 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Visonic Powermaster-360 in the language / languages: English as an attachment in your email.

The manual is 2.8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info